18
TS
L1
N
T1
T2
S3
B4
SBR
SC
USCITA
230 VAC
- JP2=ON
- JP1=OFF
PI
M
VD
FL
IG
L N
TA
LC
N
L
N
M3
M6
M5
M7
M2
CN1
JP2
JP1
1
2
C
BLOCCO
POT3
ON
POT2
ANOMALIE
JP2
JP1
J1
F1
1
2
3
4
5
6
7
5
4
3
2
1
Burner lead
Power lead
2
3
1
2
4
5
B&P MLC
B&P CP 11.01
IG
Magneto-thermal switch for electrical panel power supply
sectioning (by the installer)
SC
Boiler sensor
TA
Room thermostat
FL
Hot water micro flow switch
F1
6.3 A delayed-action fuse
PI
Heating circuit circulator
VD
Diverting valve for “micro-storage” water circuit (=OFF)
and heating system (=ON)
TS
Safety water thermostat 100
O
C (-6
°
C)
M2
Lumberg connector for boiler sensor and micro flow
switch connection
ELECTRICAL CONNECTIONS
The circulators, burner and any room thermostat should be connected following the indications in the attached
wiring diagrams. We advise you to place a bipolar switch with contacts having at least a 3 mm aperture
between the supply mains and the appliance, equipped with max. 5 A fuses. Connect the boiler to a 230 V -
50 Hz phase/neutral supply mains.
We recommend you connect the appliance to a good earth connection.
Lamborghini declines any responsibility for damage to persons or property occurring because the appliance
has not been connected to a good earth connection.
fig. 6 a
LADY S
M3
Removable terminal block for electrical panel power supply
M5
Stelvio connector for system pump connection
M6
Terminal for earth connection
M7
Removable terminal block for room thermostat
SBR
Wieland thorn 7 poles for burner
1
Boiler mode selection
2
0 - winter/summer mode selector
3
Heating potentiometer
4
Burner lock-out
5
Faults