CLIZIA D LOW NOX 24 A

14

EN

cod. 3541D140  -  Rev. 00 - 10/2012

TEST mode activation

Press the heating buttons (details 3 and 4 - fig. 17) together for 5 seconds to activate the

TEST

 mode. The boiler lights at the maximum heating power set as described in the fol-

lowing section.
The heating and DHW symbols (fig. 25) flash on the display; the heating power will ap-
pear alongside.

fig. 9 - TEST mode (heating power = 100%)

Press the heating buttons (details 3 and 4 - fig. 17) to increase or decrease the power
(Min.=0%, Max.=100%).
By pressing the DHW 

“-”

 button (detail 1 - fig. 17), boiler output is immediately adjusted

to min. (0%). By pressing the DHW 

“+”

 button (detail 2 - fig. 17), boiler output is imme-

diately adjusted to max. (100%).
If the TEST mode is activated and enough hot water is drawn to activate the DHW mode,
the boiler remains in TEST mode but the 3-way valve goes to DHW.
To deactivate the TEST mode, press the heating buttons (details 3 and 4 - fig. 17) to-
gether for 5 seconds.
The TEST mode is automatically deactivated in any case after 15 minutes or on stopping
of hot water drawing (if enough hot water has been drawn to activate the DHW mode).

Pressure adjustment at the burner

Since this unit has flame modulation, there are two fixed pressure settings: minimum and
maximum, which must be those given in the technical data table according to the type of
gas.

Connect a suitable pressure gauge to the  pressure point 

"B"

 downstream of the

gas valve.

Activate the TEST mode (see cap. 9.1).

Press the Eco/Comfort button for 2 seconds to access the gas valve Calibration
mode.

The card goes to the setting “q02”; displaying the actually saved value, by pressing
the DHW buttons .

If the pressure gauge reading is different from the nominal maximum pressure, pro-
ceed by increases/decreases of 1 or 2 units of parameter “q02” by pressing the
DHW buttons : the value is stored after each modification;  wait 10 seconds for the
pressure to stabilise.

Press the heating button “-” (ref. 3 - fig. 17).

The card goes to the setting “q01”; displaying the actually saved value, by pressing
the DHW buttons .

If the pressure gauge reading is different from the nominal minimum pressure, pro-
ceed by increases/decreases of 1 or 2 units of parameter “q01” by pressing the
DHW buttons  : the value is stored after each modification; wait 10 seconds for the
pressure to stabilise.

Recheck both adjustments by pressing the heating buttons and adjust them if nec-
essary by repeating the above procedure.

Press the Eco/Comfort button for 2 seconds to return to the TEST mode.

Deactivate the TEST mode (see cap. 9.1).

Disconnect the pressure gauge.

Heating power adjustment

To adjust the heating power, switch the boiler to TEST mode (see sec. 9.1). Press the
heating buttons detail 3 - fig. 17 to increase or decrease the power (min. = 00 - max. =
100). Press the 

reset

 button within 5 seconds and the max. power will remain that just

set. Exit TEST mode (see sec. 9.1).

Configuration Menu

Press the DHW buttons together for 10 seconds to access the configuration Menu. 7 pa-
rameters are available, indicated by the letter "b", which are not modifiable from Remote
Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.

fig. 10 - Gas valve

A

 - Upstream pressure point

B

 - Downstream pressure point

I

 - Gas valve electrical connection

R

 - Gas outlet

S

 - Gas inlet

fig. 11 - Gas valve connection

TYPE SGV100
Pi max 65 mbar
24 Vdc - class B+A

0

1

4

2

3

reset

eco

comfort

II

II

II

I I

I I I I I I

II

II

II

II

II

II

II

I I

I I I I I I

II

II

II

II

R

B

I

A

S

~ 65

Ω

~ 24

Ω

Contents Description

Range

Default

CLIZIA D LOW NOX 24 A

b01

Gas type selection

0=Natural Gas

0=Natural Gas

0=Natural Gas

1=LPG

b02

Boiler type selection

1=Bithermal instan-
taneous

1=Bithermal instanta-
neous

2=Monothermal instantane-
ous

2=Monothermal 
instantaneous
3=Heating only (3-
way valve)
4=Heating only (cir-
culating pump)

b03

Combustion chamber 
type selection

0=Sealed Chamber 
combustion control
(without fume pres-
sure switch)

0=Sealed Chamber 
with
combustion control

5=Low-Nox Open Chamber 
(with fume thermostat) 

1=Open Chamber 
(with fume thermo-
stat)
2=Sealed Chamber 
(with fume pressure 
switch)
3=Sealed Chamber 
combustion control
(with fume thermo-
stat on recuperator)
4=Low-NOx Sealed 
Chamber (without 
fume pressure 
switch)
5=Low-Nox Open 
Chamber (with fume 
thermostat)

b04

Primary Exchanger type 
selection
(b03=0)

0=Flat

0=Flat

0=Flat

1=Omega
2=--

No effect on adjustment 
(b03=1)

--

0

No effect on adjustment 
(b03=2)

--

0

Primary Exchanger type 
selection
(b03=3)

0=Flat

0=Flat

1=Omega
2=--

No effect on adjustment 
(b03=4)

--

0

No effect on adjustment 
(b03=5)

--

0

b05

Relay card LC32
operation selection 
(b02=1)

0=External gas 
valve

0=External gas valve 0=External gas valve

1=System filling 
solenoid valve
2=Solar 3-way valve

No effect on adjustment 
(b02=2)

--

0

No effect on adjustment 
(b02=3)

--

0

No effect on adjustment 
(b02=4)

--

0

b06

Mains Voltage Frequency

0=50Hz

0=50Hz

0=50Hz

1=60Hz

b07

Comfort burner on time
(b02=1)

0-20 seconds

5 seconds

5 seconds

No effect on adjustment 
(b02=2)

--

5

No effect on adjustment 
(b02=3)

--

5

No effect on adjustment 
(b02=4)

--

5

Summary of Contents for CLIZIA D LOW NOX 24 A

Page 1: ...184 216 208 131 75 234 77 9 725 5 676 5 49 5 76 5 54 51 79 5 75 5 A B C D F E 58 5 178 126 76 54 51 80 5 80 330 A B C D E F IT ISTRUZIONE PER L USO L INSTALLAZIONE E LA MANUTENZIONE EN INSTRUCTIONS F...

Page 2: ...uogo parzialmente protetto secondo EN 297 A6 per temperature fino a 5 C 15 C con kit antigelo opzionale 2 2 Pannello comandi Pannello fig 1 Pannello di controllo Legenda pannello fig 1 1 Tasto decreme...

Page 3: ...ile di funzionamento La caldaia deve essere regolata in fase di installazione dal personale qualificato Even tuali adattamenti possono essere comunque apportati dall utente per il miglioramento del co...

Page 4: ...o oppure con tubo flessibile a parete continua in acciaio inox interponendo un rubinetto gas tra impianto e caldaia Verificare che tutte le connessioni gas siano a tenuta 3 5 Collegamenti elettrici Av...

Page 5: ...ndi affinch la pressione si stabilizzi Riverificare entrambe le regolazioni attraverso la pressione dei tasti riscaldamento ed eventualmente correggerle ripetendo la procedura descritta in precedenza...

Page 6: ...ndi 5 secondi 5 secondi Ininfluente sulla regolazione b02 2 5 Ininfluente sulla regolazione b02 3 5 Ininfluente sulla regolazione b02 4 5 Indice Descrizione Range Default CLIZIA D LOW NOX 24 A P01 Off...

Page 7: ...alia Vi sono anomalie che causano blocchi permanenti contraddistinte con la lettera A per il ripristino del funzionamento sufficiente premere il tasto RESET part 6 fig 1 per 1 secondo oppure attravers...

Page 8: ...81 Elettrodo d accensione e rilevazione 19 Camera combustione 95 Valvola deviatrice 22 Bruciatore 114 Pressostato acqua 27 Scambiatore in rame per riscaldamento e sanitario 126 Termostato fumi 32 Circ...

Page 9: ...tata gas max G20 m3 h 2 73 Portata gas min G20 m3 h 1 06 Ugelli bruciatore G31 n x 18 x 0 62 Pressione gas alimentazione G31 mbar 37 Pressione gas max al bruciatore G31 mbar 35 0 Pressione gas min al...

Page 10: ...Schema elettrico fig 16 Circuito elettrico A Attenzione Prima di collegare il termostato ambiente o il cronocomando re moto togliere il ponticello sulla morsettiera 81 1kW L N 230V 50 Hz 32 L N T T 27...

Page 11: ...97 A6 for temperatures to 5 C 15 C with optional antifreeze kit 2 2 Control panel Panel fig 1 Control panel Key of panel fig 17 1 DHW temperature setting decrease button 2 DHW temperature setting incr...

Page 12: ...out its useful operating range The boiler must be adjusted at the time of installation by qualified personnel Possible adjustments can in any case be made by the user to improve comfort Compensation c...

Page 13: ...al pipe or with a continuous surface flexible s steel tube installing a gas cock between the system and boiler Make sure all the gas connec tions are tight 3 5 Electrical connections Important B The u...

Page 14: ...turn to the TEST mode Deactivate the TEST mode see cap 9 1 Disconnect the pressure gauge Heating power adjustment To adjust the heating power switch the boiler to TEST mode see sec 9 1 Press the heati...

Page 15: ...LOW NOX 24 A P01 Ignition ramp Offset 0 40 10 10 P02 Heating ramp 1 20 C minute 5 C minute 5 C minute P03 Heating standby time 0 10 minutes 2 minutes 2 minutes P04 Heating Post Circu lation 0 20 minut...

Page 16: ...ymbol detail 11 fig 17 indicating the fault code There are faults that cause permanent shutdown marked with the letter A to restore operation press the RESET button detail 6 fig 17 for 1 second or RES...

Page 17: ...gnition and detection electrode 19 Combustion chamber 95 Diverter valve 22 Burner 114 Water pressure switch 27 Copper exchanger for heating and hot water 126 Fume thermostat 32 Heating circulating pum...

Page 18: ...ner G20 mbar 2 5 Max gas delivery G20 m3 h 2 73 Min gas delivery G20 m3 h 1 06 Burner nozzles G31 no x 18 x 0 62 Gas supply pressure G31 mbar 37 Max gas pressure at burner G31 mbar 35 0 Min gas pressu...

Page 19: ...5 Wiring diagram fig 16 Electrical circuit A Attention Remove the jumper on the terminal block before connecting the room thermostat or the remote timer control 81 1kW L N 230V 50 Hz 32 L N T T 278 T...

Page 20: ...3 1 Tecla para disminuir la temperatura del ACS 2 Tecla para aumentar la temperatura del ACS 3 Tecla para disminuir la temperatura de calefacci n 4 Tecla para aumentar la temperatura de calefacci n 5...

Page 21: ...ncionamiento La caldera debe ser configurada por un t cnico a la hora de la instalaci n M s tarde el usuario puede realizar modificaciones de acuerdo con sus preferencias Curva de compensaci n y despl...

Page 22: ...rrespondiente empalme ver figura en portada seg n la normativa en vigor con un tubo met lico r gido o con un tubo flexible de pared continua de acero inoxidable interponiendo una llave de corte del ga...

Page 23: ...er a controlar las dos regulaciones mediante las teclas de ajuste de la calefac ci n y si es necesario corregirlas como se indic anteriormente Presionando la tecla Eco Comfort durante 2 segundos se vu...

Page 24: ...a lista de anomal as en orden creciente o decreciente Para ver el valor pulsar las teclas del agua sanitaria Para volver al men Service pulsar la tecla Reset La salida del men Service de la tar jeta s...

Page 25: ...ento normal de la caldera Lista de anomal as Tabla 2 3 0 5 C digo anomal a Anomal a Causa posible Soluci n A01 El quemador no se enciende Falta de gas Controlar que el gas llegue correcta mente a la c...

Page 26: ...eguridad 81 Electrodo de encendido y detecci n 19 C mara de combusti n 95 V lvula desviadora 22 Quemador 114 Presostato del agua 27 Intercambiador de cobre para calefacci n y ACS 126 Termostato de hum...

Page 27: ...esi n m nima quemador con G20 mbar 2 5 Caudal m ximo G20 m3 h 2 73 Caudal m nimo G20 m3 h 1 06 Inyectores quemador G31 n x 18 x 0 62 Presi n de alimentaci n G31 mbar 37 Presi n m xima quemador con G31...

Page 28: ...el ctrico fig 16 Circuito el ctrico A Atenci n Antes de conectar el termostato de ambiente o el reloj programa dor a distancia quitar el puente de la regleta de conexiones 81 1kW L N 230V 50 Hz 32 L...

Page 29: ...1 JOANNES CLIZIA D LOW NOX 24 A EN 297 A6 5 C 15 C 2 2 1 49 1 2 3 4 5 6 7 8 9 10 11 12 Eco 13 14 15 16 17 11 49 d2 11 49 d1 Comfort 11 49 cap 19 4 11 49 d3 d4 2 3 5 7 49 5 2 7 49 5 3 B sez 18 3 0 1 4...

Page 30: ...ECO eco comfort 7 49 ECO 12 49 7 49 3 49 5 6 49 CU 1 49 1 10 0 3 49 OF 1 49 54 5 6 49 6 A 10 1 17 49 1 0 F37 1 55 7 3 3 1 3 2 EN 297 pr A6 5 C 15 C I I I I I I I I I I I I I I I I I I ECO 7 49 7 49 20...

Page 31: ...24 A 31 RU cod 3541D140 Rev 00 10 2012 A 3 3 B B 25 Fr 1 F 10 CaCO3 3 4 3 5 B Y 3 3 A B HAR H05 VV F 3x0 75 2 8 B 230 64 8 3 6 0 5 B 4 4 1 1 cap 20 2 1 2 49 10 b01 1 2 49 00 01 49 1 2 10 3 4 1 2 3 4 5...

Page 32: ...T sez 19 1 10 7 b 10 A B I R S 11 TYPE SGV100 Pi 65 24 B A 0 1 4 2 3 reset eco comfort I I I I I I I I I I I I I I I I I I I I I I I I I I I I II I I I I I I I I I I I I I I R B I A S 65 24 CLIZIA D L...

Page 33: ...2 4 0 4 C 2 C P08 b02 1 0 60 30 60 b02 2 0 60 60 b02 3 0 60 30 b02 4 0 60 30 P09 b02 1 50 65 C 50 C 55 C b02 2 50 65 C 55 C b02 3 50 65 C 65 C b02 4 50 65 C 65 C P10 b02 1 70 85 C 70 C 0 b02 2 0 b02 3...

Page 34: ...History 11 H1 H10 Service Reset Service Reset 20 20 rE History 3 Eco comfort Hi story Service Service Reset 20 20 4 2 cap 20 4 3 12 1 4 4 11 49 A RESET 6 49 1 RESET F 2 3 0 5 A01 A02 A03 F04 20 F05 A...

Page 35: ...7 F39 A41 F42 F43 H 2O F50 7 44 8 56 9 72 10 74 11 78 14 81 19 95 22 114 27 126 32 138 36 139 37 194 38 241 39 278 42 290 27 19 14 36 114 32 39 38 37 44 95 42 194 22 81 278 11 9 7 8 10 56 126 78 74 29...

Page 36: ...P 24 0 9 2 Pmax 80 60 C 93 0 30 92 7 92 42 EEC NOx 5 70 NOx G20 x 18 x 1 00 G20 20 0 G20 14 0 G20 2 5 G20 3 2 73 G20 3 1 06 G31 x 18 x 0 62 G31 37 G31 35 0 G31 5 8 G31 2 00 G31 0 78 3 PMS 0 8 C 90 tm...

Page 37: ...CLIZIA D LOW NOX 24 A 37 RU cod 3541D140 Rev 00 10 2012 5 5 16 A 81 1kW L N 230V 50 Hz 32 L N T T 278 T 42 4 3 2 1 44 38 114 ABM01 LC32 3 2 1 95 126 72 139 138...

Page 38: ...rmit Il costruttore dichiara che questo apparecchio conforme alle seguenti direttive CEE Direttiva Apparecchi a Gas 2009 142 Direttiva Rendimenti 92 42 Direttiva Bassa Tensione Direttiva Compatibilit...

Page 39: ......

Page 40: ...95 GRUGLIASCO TORINO ITALIA TEL 011 40221 CAS POSTALE 1393 10100 TORINO TELEX 220364 IOTERM I TELEGR TF78 42 42 JOANNES TORINO TELEFAX 011 780 40 59 BRUCIATORI DI GASOLIO GAS NAFTA CALDAIE MURALI A GA...

Reviews: