Table 3-3 selection of DC circuit breaker:
Model
Recommended parameters of DC circuit
breaker
JNP370L
440VDC,20A
JNP370LS
440VDC,20A
JNP550L
440VDC,20A
JNP550LS
440VDC,20A
Notice!
1. It must be DC breaker, it’s prohibited to be
replaced by AC breaker;
2. Shown as right side picture DC breaker
should be 2 stages.
3.2 Cable Selection for Electrical
Connection
Table 3-4 users can select the electrical connection cable
according to the following specifications:
Model
Cable range
(
AWG
)
DC side
AC side
PV+
、
PV-
U
、
V
、
W
PE
JNP370L
14-12
14-12
12
JNP370LS
14-12
14-12
12
JNP550L
14-12
14-12
12
JNP550LS
14-12
14-12
12
PV+
PV+
PV-
PV-
DC Breaker