24
Weak
sunshine
Inverter
shutdown.
When
malfunction
disappear,
inverter can
restart
automatic.
Array output
low.
Usually appears
in early morning,
dusk and cloudy
days. This
situation is aim
to protect the
motor of pump
and lengthen the
lifetime.
Overflow
alarm
Inverter
shut down
until the
water level
recover or
protection
recover
time is up,
the machine
will restart
automaticall
y.
Water level
in container
higher than
high-end
level
sensor.
If this situation
appears more
than once,
please check
onsite and set
the water level
sensor at a
proper height.
Output
over-loa
d
Inverter
shutdown
and will
restart
automaticall
y after the
fault
disappears.
Load higher
than rated
output
power of
inverter.
Please make
sure the system
is proper
designed. The
power of pump
motor should not
be larger than
inverter output.