21
6 Electrical Connection
The electrical connection can be carried out when the mechanical installation
of inverter is completed. The following operation specification must be
followed when making electrical connection.
Warning
!
●
All the electrical connection must meet local electrical connection
standard.
●
Only qualified electrical personnel can perform the wiring installation
work.
●
Incorrect
wiring operation may cause operating casualties or
equipment damage permanently.
●
Ensure that there is no electricity in DC side before the electrical
connection.
●
Grounding correctly, using proper conductor and taking necessary
Short-circuit protection to ensure the safe operation of inverter.
●
Don’t try to switch on any breaker before all the electrical connection is
finished.
6.1 Connecting Terminals of Inverter
All connecting terminals are at the bottom of the inverter, and the cross
screwdriver is used to remove the terminal cover, which contains DC side
input (PV) terminal, AC side input (motor) terminal, communication terminal
and water level sensor terminal. The DC side input terminal, AC side input
and output terminal, and the grounding terminal are connected by a terminal
block; the communication terminal and water level sensor terminal are
connected by a signal terminal block, as shown in the figure below.