background image

Charge cycles:

The charge cycles of new battery chargers have been specially developed to optimise charging of all commer-

cially available batteries. The variety of technologies employed in batteries available today in retail demand 

different charging characteristics to ensure correct and complete charging. JMP Skan chargers guarantee the 

right charge cycle for every type of battery, thus extending the life of your batteries. 

1. First diagnostic step: “Diagnostic I”  

    (initial diagnosis) 

The charger analyses the battery charge level and 

determines the optimum charging mode.

2. First charging step: “Repair Mode”  

    (desulfation)

Charging with pulse current until the battery 

achieves the optimum voltage and current values 

to commence the next charging step.

3. Second charging step: “Initial Charge”  

    (battery activation) 

Charging with reduced, constant current.

4. Third charging step: “Bulk Charge” 

    (charge with constant current) 

Charging with constant current until maximum 

battery voltage is achieved.

5. Fourth charging step: “Absorption Charge” 

    (charge with constant voltage)

Charging with stabilised voltage until complete 

charging is achieved.

6. Second diagnostic step: “Diagnostic II” 

    (second diagnosis) 

The charger checks the status of the charged 

battery. 

7. Fifth charging step: “Float Mode” 

    (trickle charging with constant voltage)

Trickle charging with constant, reduced voltage.

8. Sixth charging step: “Trickle Mode” 

    (trickle charging with pulse current)

Trickle charging with pulse current (constantly 

available).

Safety precautions:

JMP Skan chargers are equipped with protective features that ensure maximum safety during operation 

and use of the device.

•  Complete protection against sparking

•  Protection against short circuiting

•  Voltage compensation

•  Overheating protection

•  Protection against reverse polarity

•  Protection against weather conditions
(IP65: Protected against total dust ingress and low pressure water jets from any direction)

JM-Products

Hammerbrookstr. 97 
20097 Hamburg
Deutschland
Tel.: + 49 (0) 40 2 37 21-0
www.jmproducts.eu

Summary of Contents for Skan 4.0

Page 1: ...and acid rinse the skin off and the eyes out immediately under flowing water and consult a doctor Always wear protective goggles when connecting and disconnecting the battery and keep the battery away from the face Keep out of reach of children This device is not a toy and should not be used as such This device should not be used by persons including children with limited physical sensory or menta...

Page 2: ...arge retention of 12 V batteries from 4 Ah to 70 Ah Suitable for charging of lithium or standard batteries 4 A Charging of 12 V batteries from 30 Ah to 80 Ah Charge retention of 12 V batteries from 30 Ah to 120 Ah Suitable for charging of lithium or standard batteries Charging of 12 V batteries from 30 Ah to 80 Ah with 4 A Charge retention of 12 V batteries from 30 Ah to 120 Ah Suitable for chargi...

Page 3: ...ositive terminal on the battery Battery analysis and fault signals The charger is capable of checking the battery status prior to and during charging and indicating any connec tion faults between the charger and the battery to be charged This occurs via a digital display on which the error code is indicated The following indications can appear in the event of faults during charging Display message...

Page 4: ... current Charging with constant current until maximum battery voltage is achieved 5 Fourth charging step Absorption Charge charge with constant voltage Charging with stabilised voltage until complete charging is achieved 6 Second diagnostic step Diagnostic II second diagnosis The charger checks the status of the charged battery 7 Fifth charging step Float Mode trickle charging with constant voltag...

Reviews: