SECTION 3 - MACHINE OPERATION
1001070465
LIFTPOD by JLG
3-18
Powerpack Emergency Stop/Shutdown Button
If the platform stops responding to operator input at any time while
the platform is moving, use the emergency stop button to cut the
power to the motor.
Unpowered Descent
The platform manual descent crank (Figure 2-8.) is provided to:
• Allow the platform operator to lower the platform in the
event that the cordless drill or powerpack batteries run out
of sufficient charge to lower the platform;
• Allow ground personnel to lower the platform in event that
the platform operator becomes incapacitated.
For emergency operation please see Section 4 - Emergency Pro-
cedures.
Figure 3-23. Emergency stop button operation
Press down to activate
Rotate clockwise
Emergency Stop
to release/reset
Emergency Stop
Go to Discount-Equipment.com