SECTION 7 - DIAGNOSTIC TROUBLE CODES
3121788
7-3
009
DRIVE PREVENTED – ELEVATED
ABOVE DRIVE CUTOUT HEIGHT
None
None
• Drive State = PREVENTED
The Drive Cutout functionality is enabled, and the
Platform is Elevated above the Calibrated Cutout
Height. (Refer to Drive Cutout Functionality)
•
(Machine Setup-> Drive Cut-Out=YES) AND
the Platform Height Value > DriveCutValue
X
211
POWER CYCLE
None
2_1
• No Motion restrictions
This Help Message is issued at each power-up.
This serves to indicate which messages have
been recorded in the failure log since the last
power-up event.
X
212
KEYSWITCH FAULTY
None
2_1
• Force to Ground Mode
Both the Ground Select and Platform Select sig-
nals are energized, which means there is an issue
with the keyswitch or one of the lines are
shorted to battery.
•
V4-20 PF_SEL and V1-5 GRND_SEL are ener-
gized simultaneously.
X
221
FUNCTION PROBLEM – HORN
PERMANENTLY SELECTED
None
2_2
• Horn Prevented
Horn Switch in the Platform Control Box was
closed during power-up. Release or repair the
switch to clear the message.
•
In Platform Mode and HORN is Energized dur-
ing PlatformMode Startup. Retained until
HORN is momentarily De-energized.
X
2210 TRIGGER CLOSED TOO LONG
WHILE IN NEUTRAL
None
2_2
• Trigger State = FALSE there-
fore
• DriveState = PREVENTED
• Lift Up State = PREVENTED
• LiftDownState = PREVENTED
Trigger Switch in the Platform Control Box was
closed for more than five seconds while the Joy-
stick (accelerator) was in the neutral position
(centered). Release switch or repair the switch /
wiring to clear the difficulty.
•
In PlatformMode, the TRIGGER input was
Energized for 5,000mS AND JoystickCom-
mand is 0% and Stable (/- 0.05V
change). Retained until the TRIGGER input is
momentarily De-energized.
X
222
FUNCTION PROBLEM – INDOOR
/ OUTDOOR PERMANENTLY
SELECTED
None
2_2
• Previously selected Indoor /
Outdoor Mode maintained
Indoor / Outdoor Switch in the Platform Control
Box was closed during power-up. Release or
repair the switch to clear the message.
•
In PlatformMode, the IN/OUT switch is ener-
gized during PlatformMode Startup. Retained
until IN/OUT is momentarily De-energized.
•
Only applicable if {MACHINE SETUP-> MAR-
KET = CSA, CE, AUSTRALIA, or GB}
X
223
FUNCTION PROBLEM – DRIVE &
LIFT ACTIVE TOGETHER
None
2_2
• MoveState = LIFT
• DriveState = PREVENTED
• LiftUpState = PREVENTED
• LiftDownState = PREVENTED
The Drive - Lift Selector Switch indicates that
both functions are selected simultaneously.
Repair the wiring or switch to clear the message.
•
In PlatformMode and DRIVE_SEL and
LIFT_SEL are energized at the same time.
Retained until either is momentarily open cir-
cuit.
X
Table 7-1. Diagnostic Trouble Codes (DTC)
DTC
Help Message
Alarm
Flash
Code
Action
Trigger