SECTION 6 - LSS (LOAD SENSING SYSTEM) SERVICE
3121788
6-3
6.2
ANALYZER INFORMATION
Personalities Menu
The following parameter in the PERSONALITIES, LOAD
menu adjust performance of the LSS. All adjustments
must be made in Access Level 1 (33271).
Diagnostic Menu
The Diagnostic Load menu's are another troubleshoot-
ing tool for the Load Sensing System. Sensor and status
information is presented in real-time for the technician.
To access the Diagnostic Menu, use the LEFT and RIGHT
Arrow keys to select DIAGNOSTICS from the Top Level
Menu. Press the ENTER key to select the menu.
NOTE:
The Diagnostic Load menu's are not available when
the LSS is not enabled. (Machine Setup, Load is set to
0=Not Installed
Press the LEFT and RIGHT arrow keys to view the load
and angle sub-menu and press the enter key. Once in
the load and angle submenu, press the LEFT and RIGHT
arrow keys to view the various displays.
The Table 6-2 details the structure of the Diagnostic,
Load Menu, and describes the meaning of each piece of
information presented.
Table 6-1. Personalities Menu Description
SUBMENU
(Displayed on
Analyzer 1st line)
PARAMETER
(Displayed on
Analyzer 2nd Line)
DESCRIPTION
LOAD:
OVR DBNCE:
0.3 S
This parameter sets the
debounce time (in sec-
onds) where platform
load must be greater
than the capacity limit
before triggering over-
load
OVR HOLD:
5.0 S
This parameter sets the
minimum hold time (in
seconds) where plat-
form load must be less
than the capacity limit
before releasing over-
load.
ACC'Y:
0 KG
This parameter reduces
the capacity limit for
permanently mounted
platform accessories.
Table 6-2. Diagnostic Menu Descriptions
DIAGNOSTICS MENU
(Displayed on Analyzer 1
st
Line)
PARAMETER
(Displayed on Analyzer
2
nd
Line)
PARAMETER VALUE
(Displayed on Analyzer
2
nd
Line)
DESCRIPTION
DIAGNOSTICS:
LOAD
Menu available only when Machine Setup’s LOAD is
CUTOUT PLTM or CUTOUT ALL
OVERLOADED?
NO
NO/YES
Displays NO when the platform load is within rated
capacity of the vehicle; YES when platform load is
excessive
PRES1 RAW:
0.00 mA/V
mA or Volts
Displays the lift cylinder head pressure 1 raw reading;
shown as volts for 3246R and mA for all remaining
models
PRES1:
XXXX PSI
0.0-9999.9 PSI
Displays the lift cylinder head pressure 1 scaled read-
ing in PSI
PRES1:
XXXX.X BAR
0.0 to 9999.9 BAR
Displays the lift cylinder head pressure 1 scaled read-
ing in BAR
PRES2 RAW:
00.00 mA/V
mA or Volts
Displays the lift cylinder head pressure 2 raw reading;
shown as volts for 3246R and mA for all remaining
models