4
JL AUDIO
CleanSweep
®
CL-SES
POWER CONNECTIONS
Before installing the CL-SES, disconnect the
negative (ground) wire from the vehicle’s battery.
This will prevent accidental damage to the system,
the vehicle and your body during installation.
The CL-SES has a three-wire inline jack located
next to the “
Manual Override Connector
”. This
jack accepts the following connections:
“
+12 V
”: Co12V
“
GND
”: Chassis Ground
“
IGN
”: Sw12V
Since the CL-SES does not draw very much
current during operation, 18 AWG - 16 AWG wire
is ample for making all of these connections. Use
good-quality crimp connectors (or solder and heat
shrink tubing) to join the harness leads to any
extended wires. Any wires that run through metal
barriers (such as firewalls), must be protected with
a high quality rubber grommet to prevent damage
to the insulation of the wire. Failure to do so may
result in a dangerous short circuit.
The “
IGN
” connection is designed to do the
following: the CL-SES will only turn on when
+12V is present at this connection. Conversely,
the CL-SES will shut off as soon as +12V is
removed from this connection. This prevents the
CL-SES from remaining on. Connect the “
IGN
”
wire to a 12-volt circuit in the vehicle that is only
energized with the key in the “Accessory” (ACC)
or “Ignition” (IGN) positions.
Ideally, the “
+12V
” (constant) and “
GND
”
(chassis ground) connections should be run to
the same distribution points that the amplifiers
use for their power and ground connections. This
minimizes the possibility of noise in the system.
A constant 12-volt connection is necessary for the
CL-SES to “remember” the last selected source
when used in the “manual” switching mode.
FUSE REQUIREMENTS
The “
+12V
” constant wire on the CL-SES
power harness has an inline 1 amp, fast blow AGC
(small glass-bodied) fuse for protection of the
unit. Do not remove this fuse or replace it with a
different value of fuse.
OUTPUT CONNECTIONS
Two RCA-type jacks provide two-channels of
analog audio output to feed the auxiliary input of
the head unit or OEM Interface Processor. These are
located next to the “
Manual Override Connector
”
and are clearly labeled for each channel.
Summary of Contents for CleanSweep CL_SES
Page 11: ...JL AUDIO CleanSweep CL SES 11 ...