PAGE 31 of 42
BT0179 Rev 04.5
Chapter 8
TROUBLESHOOTING
Problem
Possible Cause
Solution
Can not close
the side mounted
lever on the pivot
nose/tail.
The rosettes of the
lever and the pivot are
not lined up.
Slightly wiggle the pivot nose/tail while
locking the side mounted lever allowing the
rosettes to properly seat.
Insufficient probe
contact.
Scanner not set
properly.
Reconfigure the scanner as per instructions
(see Probe Holder Adjustment on page 13)
Encoder not
working.
Wing knob on bottom
of cart not tight
enough and umbilical
is loose.
Remove cart handle and ensure the umbilical
is properly plugged into the cart body.
Tighten the black wing knob and ensure
no movement of the umbilical housing is
possible.
Magnetic wheels
become loose.
Brakes are engaged.
Ensure the brake is unlocked when using the
scanner
(see Brake Handle on page 7)
8.1. Technical Support
For technical support, contact Jireh Industries
(see Jireh Industries Ltd. on page 1).