background image

 

 

 

Page 8 of 25 

 

 

 

 

FIG.5-3b  Starting Auto Connecting 

 

When the auto connecting is failed, the device will retry after 15-second countdown, 

unless you cancel it, show as FIG.5-3c. 

 

FIG.5-3c Auto Connecting Retry 

 

5.4  Control Centre 

As FIG.5-4a shows, administrator password should be provided before enter the control 

centre. 

 

FIG.5-4a  Login to Control Centre 

 Note, If there is none administrator password setting, the device will skip FIG.5-4a 

dialog and enter control centre directly. Please refer to chapter 5.12 to set administrator 

password.  

Summary of Contents for J60

Page 1: ...J60 Thin Client User Guide Version 1 7 ShenZhen JIEYUN Technology Co Ltd www jieyung com Updated at 2014 06 28 ...

Page 2: ...Please do not copy extract or publish any content of this document without the owner s permission The copy rights of the third party logo mentioned in this document belong to their owners Formatting Conventions XXX Menu or Button XXX Window or Display UI Warning ...

Page 3: ...5 5 CONNECTION SETTINGS 9 5 6 ADD DESKPOOL CONNECTION 11 5 7 ADD MICROSOFT RDP CONNECTION 11 5 8 ADD SPICE CONNECTION 13 5 9 ADD OVIRT CONNECTION 14 5 10 DISPLAY PROPERTIES 15 5 11 NETWORK SETTINGS 16 5 12 NETWORK DIAGNOSIS 18 5 13 SYSTEM 18 6 RESTORE FACTORY DEFAULT SETTINGS 23 7 FAQ 23 7 1 HOW TO RESTORE DEFAULT RESOLUTION 23 7 2 HOW TO FIX RDP FAILURE 24 7 3 HOW TO RESOLVE THE AUDIO PROBLEM WIT...

Page 4: ...e Up to 1080p resolution and 32bpp color depth Small and exquisite without fan Very low power consumption Support multiple enhanced protocols such as RDP RemoteFX and SPICE Support smoothly on line video Support high definition video file play with redirection plugin Easy firmware upgrade Support USB redirection 2 Interfaces and mounting options FIG 2 1 Interfaces FIG 2 2 Mounting Options ...

Page 5: ...ug Port Mini USB port for debug VGA Up to 1920 x 1080 60Hz 32bpp color depth HDMI Up to 1920 x 1080 60Hz 32bpp color depth Power Input DC 5V 2000mA Power Switch Light push power switch Power Adapter Input AC 100 240V 50 60Hz Output DC 5V 2000mA Lock Slot Kensington lock slot Size Height 29 5mm Width 150mm Depth 115 mm Power Consumption 7W Cooling None fan Noise 0db Temperature range 0 45 C Humidit...

Page 6: ...a HDMI or DVI interface the HDMI cable or HDMI to DVI converter could take the place of VGA cable 5 System Guide Please install the J60 thin client device as FIG 4 1 shows 5 1 Boot Screen FIG 5 1 Boot Screen When the thin client power on monitor will display the boot screen as FIG 5 1 shows there is a progress bar under the logo stands for the boot status While success boot the device goes to Netw...

Page 7: ...to connecting phase FIG 5 2 Network Initialization Note if fail to initialize the network please check the following possible reason 1 No available cable connection 2 If the device is set to use dynamic IP address and fail to acquire IP settings from DHCP server please check the DHCP services 5 3 Auto Connecting If there is none automatic connection setting the device will skip the auto connecting...

Page 8: ... 5 3c FIG 5 3c Auto Connecting Retry 5 4 Control Centre As FIG 5 4a shows administrator password should be provided before enter the control centre FIG 5 4a Login to Control Centre Note If there is none administrator password setting the device will skip FIG 5 4a dialog and enter control centre directly Please refer to chapter 5 12 to set administrator password ...

Page 9: ...gement the remote desktop connections Display Properties Resolution and language settings Network Settings Network parameters Network Diagnosis Diagnose the network with ping System Show the system information and system level functions 5 5 Connection Settings Click Connection Settings menu enter the connection setting window shown as FIG 5 5a the table surrounded by red dotted line is connection ...

Page 10: ...t RDP client with RemoteFX graphic feature enabled SPICE Connection Remote SPICE server connection configuration make use of RedHat SPICE protocol oVirt Connection oVirt VDI accessing configuration Notice the web portal would act as an entry of a remote desktop system instead of a standard web browser Connection List The connection table includes the following items Name Connection name Type Deskp...

Page 11: ...nt check box please fill the deskpool login account information User Name A deskpool user name Password Password of the deskpool user 5 7 Add Microsoft RDP Connection Click Add Microsoft RDP Connection popup the Add MS RDP Connection dialog as FIG 5 7a shows Input the following information before click OK button Connection Name Name of this connection Server Address Address of remote desktop serve...

Page 12: ...e desktop user Domain Domain name If no domain server keep empty FIG 5 7a Add Microsoft RDP Connection FIG 5 7b show the options for Microsoft RDP connection include the personalized options and the auto run program FIG 5 7b Microsoft RDP Options ...

Page 13: ... the option will be invalid In addition when the RemoteFX successfully enabled it will adopt the 32bpp color depth automatically FIG 5 7c show the experience settings for Microsoft RDP connection and the default selections FIG 5 7c Microsoft RDP Settings 5 8 Add SPICE Connection Click Add SPICE Connection popup the Add SPICE Connection dialog as FIG 5 8 shows ...

Page 14: ...evices Automatically redirect local devices ti the VM If you check the Enable Security Connection check box please fill the security information Security Port Security port for the security connection Certificate Certificate for the security connection You can manage the certificates at System setting window 5 9 Add oVirt Connection Click Add oVirt Connection popup the Add oVirt Connection dialog ...

Page 15: ... Add oVirt Connection 5 10 Display Properties Click Display Properties menu enter the display properties window shown as FIG 5 10a FIG 5 10a Display Properties Resolution Setting Select a resolution at Resolution list box and click Save button a notification dialog will be popped up shown as FIG 5 10b to confirm the change ...

Page 16: ...t to restore the original setting FIG 5 10c Notification to Accept Resolution Setting The monitor maybe show black screen when it is not comparable with the resolution changing please do nothing just wait for the device restore to the original resolution automatically Language Setting You can change the language setting by selecting 简体中文 or English at language list box and then click Save button t...

Page 17: ...re none IP address conflict Click PPPoE button enter the PPPoE setting window shown as FIG 5 11b PPPoE settings Input the account for PPPoE connection in Username and Password edit boxes and press Connect button to start the PPPoE connection Save button is used to save the account information If you select the Auto Connect check box the device will start the PPPoE connection automatically when it ...

Page 18: ...nu enter the network diagnosis window shown as FIG 5 12 FIG 5 12 Network Diagnosis In the Network Diagnosis window You can check whether the network connection or destination server is available with ping operation in additional the parameters of ping command could be adjusted 5 13 System ...

Page 19: ...s System Name Product Name Product Key Disk Capacity Memory Capacity CPU Info Wired NIC Wireless NIC Image Release Time Software Information The software information includes the following entries Operation System RDP Protocol SPICE Deskpool VDI Agent Click Voice button enter the voice setting window shown as FIG 5 13b There are earphone volume and microphone volume settings ...

Page 20: ...e is used for SPICE security connection You can download SPICE certificate to the local device The downloaded certificate will be listed and could be deleted by the Delete button FIG 5 13c SPICE Certification Click Operation button enter the operation button window shown as FIG 5 13d There are Restart Upgrade Export Log and Password buttons ...

Page 21: ... update jytc file to root directory of the USB storage Phase II upgrade the firmware 4 Power on the thin client and remember the value of Firmware Version at System window 5 Insert the USB storage to the device 6 At System window click Upgrade button and confirm the operation 7 System prompt System is upgrading please wait After a few minutes the device will reboot automatically 8 If there is a ne...

Page 22: ...latest log file at root directory named system tar gz Change Password Click Password button to set or change the administrator password shown as FIG5 13e FIG 5 13e Change Password Note 1 None administrator password with the factory default settings 2 If lost the administrator password please refer to chapter 6 to restore the factory default settings Click Time button enter the time setting window ...

Page 23: ...ing Step 2 Press Ctrl Alt Shift F2 Step 3 Click Confirm button in the notification dialog shown as FIG 6 1 The device will reboot to restore the factory default setting FIG 6 1 Confirm Dialog to Reset System 7 FAQ 7 1 How to restore default resolution Three steps to restore the device output resolution to default setting with 800x600 Step 1 Power on and waiting for the end of boot screen Shown as ...

Page 24: ...io problem with google chrome browser With the recent release of Google Chrome Version 21 and later Google made a change and instead of using Adobe s Flash they now use something new called Pepper Flash The problem is that the Pepper Flash cannot work well with Microsoft RDP which will degrade the remote audio mapping Please follow the steps below to disable the new Pepper Flash 1 Open the chrome ...

Page 25: ...be Flash Plugin for non Internet explorer browsers 5 The first plugin listed in the flash section is the pepper flash implementation You can tell that the first one is pepper flash by looking for Pepper Flash in the Location string See yellow highlight below 6 Find the Disable link and click that link 7 Now close all open chrome windows and tabs and restart chrome and it should work well with remo...

Reviews: