Single phase ammeter 

 Set communication address 

 

Set data format 

 

Set baud rate 

 

Three phase ammeter 

 Set communication address 

 

Set data format 

 

Set baud rate 

 

If the parameters of third level data are modified, please press 

  button to save the modified 

data and return to secondary level. If user presses Menu button, the modified data will not be saved. 

If user wants to exit program setting interface, please return to first level of program setting 

interface, then press Menu button to see 

--

, now there are two choices available: 

1. Press 

  button to exit program setting interface without saving modified data; 

2. Press 

 or 

 button to switch to 

--

, then press 

 button to exit 

program setting interface and save modified data. 

 

For more detailed parameters, please log on our website. 

http

//www.jcsepi.com 

JIANGSU SFERE ELECTRIC CO., LTD. 

Add

99 Chengjiang R.(E), Jiangyin, Jiangsu, China 

P.C: 214429 

Tel

(0510)86199988 86199080 

Fax

(0510)86199081 

http

//www.meter-sfere.com 

Email:[email protected]    [email protected]

 

Summary of Contents for SI Series

Page 1: ...Digital Display AC Ammeter Operation Guide Applied to SI series S3I series JIANGSU SFERE ELECTRIC CO LTD...

Page 2: ...detecting device should be used to guarantee no voltage in any part of the meter The electrical parameters supplied to the meter should be within the rated range The following situations may result i...

Page 3: ...splay mode Null LED Y LCD Cutout size 96 91mm 91mm 80 76mm 76mm 72 67mm 67mm Function code current Phase Null single phase 3 three phase Abbreviation for SFERE 3 Panel 1 Model 2 Display measured data...

Page 4: ...L N Communication 58 A B S 59 60 PC RS232 RS485 4 C B 9 5 6 A 7 8 Three phase current input IA I I A B IB C I C I 4 I 5 Single phase current input I Relay output 28 29 31 32 1DO 2DO DIC 1DI 2DI 3DI 7...

Page 5: ...ress Primary voltage v alue Baud rate Remote control mode Flashing alarm Brightness degree Programming password Cycle display time Secondary voltage value Delay time Hysteresis value Alarm value Alarm...

Page 6: ...rogramming password Secondary voltage v alue Delay time Hysteresis value Alarm value Alarm item Software version Lower limit value of analog output range Analog output mode Upper limit value of analog...

Page 7: ...nge input primary value at field After entering setting interface press or button to select then press button to enter signal setting interface now press or button to select Single phase voltage meter...

Page 8: ...ace please return to first level of program setting interface then press Menu button to see now there are two choices available 1 Press button to exit program setting interface without saving modified...

Reviews: