Digital display ammeters measure three phase or single phase current parameters of grid by 

adopting AC sampling technology. This series of meters support RS-485 communication interface 
(Modbus-RTU protocol), analog output, digital input and relay output function. The transmission 
ratio can be changed through the operation buttons on the panel of meter. 

 

2. Naming Rule

 

S

I

    

 - 

Optional function: C - RS485 communication
                              M - Analog output
                                J - Relay output
                               K - Digital input

Display mode: Null - LED
                             Y - LCD

Cutout size: 96 - 91mm×91mm

80 - 76mm×76mm
72 - 67mm×67mm

Function code

current

Phase

Null - single phase

          3 - three phase

Abbreviation for SFERE

 

3. Panel

 

 

 

1. Model

 

2. Display measured data and 

programming information

 

3. Unit

 

4. Left-forward button that is 

used to select functions or select 

numbers at different bits

 

5. Right-forward button that is 

used to select functions or change 

the number at selected bit

 

6. Menu button that is used to 

enter parameter setting status, 

return to upper level menu in 

programming status and cancel an 

operation

 

7. Enter button that is used to 

confirm an operation. 
 
 

SI series panel

A

A

Menu

M e n u

A

B

C

A

A

A

A

B

C

A

A

A

S3I series panel

Summary of Contents for SI Series

Page 1: ...Digital Display AC Ammeter Operation Guide Applied to SI series S3I series JIANGSU SFERE ELECTRIC CO LTD...

Page 2: ...detecting device should be used to guarantee no voltage in any part of the meter The electrical parameters supplied to the meter should be within the rated range The following situations may result i...

Page 3: ...splay mode Null LED Y LCD Cutout size 96 91mm 91mm 80 76mm 76mm 72 67mm 67mm Function code current Phase Null single phase 3 three phase Abbreviation for SFERE 3 Panel 1 Model 2 Display measured data...

Page 4: ...L N Communication 58 A B S 59 60 PC RS232 RS485 4 C B 9 5 6 A 7 8 Three phase current input IA I I A B IB C I C I 4 I 5 Single phase current input I Relay output 28 29 31 32 1DO 2DO DIC 1DI 2DI 3DI 7...

Page 5: ...ress Primary voltage v alue Baud rate Remote control mode Flashing alarm Brightness degree Programming password Cycle display time Secondary voltage value Delay time Hysteresis value Alarm value Alarm...

Page 6: ...rogramming password Secondary voltage v alue Delay time Hysteresis value Alarm value Alarm item Software version Lower limit value of analog output range Analog output mode Upper limit value of analog...

Page 7: ...nge input primary value at field After entering setting interface press or button to select then press button to enter signal setting interface now press or button to select Single phase voltage meter...

Page 8: ...ace please return to first level of program setting interface then press Menu button to see now there are two choices available 1 Press button to exit program setting interface without saving modified...

Reviews: