background image

5

SENATOR G2 MANUAL -  HIGH PRESSURE CLEANER

Figure.1 - Senator G2 Cold Water Petrol High 
Pressure Cleaner

Figure.2 - Senator G2 Cold Water Petrol High Pressure Cleaner 
with optional trolley kit

Standard equipment

A Jetwave Senator

 G2 High Pressure Cleaner comes 

with:
•  High Pressure gun & back part lance
•  Variable dual lance with high and low nozzles (or 

straight lance on 350 bar models)

•  15m of DWB 3/8” high pressure hose
•  Engine Operator’s Manual
•  Operator’s Manual
•  (Optional) Trolley Kit
•  (Optional) Water Tank
•  (Optional) Hose Reel

See the Jetwave

®

 catalog for specific equipment supplied 

with each catalog number.

Description, Specifications and 
Standard equipment 

Description

The Jetwave

® 

Senator

™ 

G2 engine powered High Pressure 

Cleaner machine is a portable unit designed to use a 
combination of water pressure and flow to clean different 
surfaces from dirt, grease, & grime. Water is pumped 
through the high pressure plunger pump at increased 
pressure and flow allowing water to be used at such high 
pressure to remove dirt and grime from surfaces. The
Senator

 G2 High Pressure Cleaner is equipped with a 

gasoline HONDA

 engine to drive the triplex plunger pump.

Figure.3 - Machine Serial Number

Note: Range & Product is subject to change at anytime.

MODEL

CLASS

(AS/NZS: 4233)

PUMP

PRESSURE

(PSI/BAR)

FLOW RATE

(L/PM)

NOZZLE 

SIZE

PETROL ENGINE

UNIT 

APPROX

WEIGHT 

(KG)

MACHINE 

DIMENSIONS 

SKID (mm)

Senator G2

A (5,500 BAR/

LITRES)

JW Triplex 

Plunger

4000 / 275

20

05

HONDA GX630 

OR iGX700

195

800(L)x550(W)

x765(H)

Senator G2

B (6,300 BAR/

LITRES)

JW Triplex 

Plunger

4350 / 300

21

055

HONDA GX690

OR iGX700

195

800(L)x550(W)

x765(H)

Senator G2

A (5,520 BAR/

LITRES)

JW Triplex 

Plunger

5000 / 345

16

04

HONDA GX630

OR iGX700

195

800(L)x550(W)

x765(H)

Senator G2

B (8,050 BAR/

LITRES)

JW Triplex 

Plunger

5075 / 350

23

055

HONDA GX690

OR iGX700

195

800(L)x550(W)

x765(H)

Senator G2FI

B (8,680 BAR/

LITRES)

JW Triplex 

Plunger

4060 / 280

31

08

HONDA iGX800

200

800(L)x550(W)

x765(H)

Senator G2FI

B (8,750 BAR/

LITRES)

JW Triplex 

Plunger

5075 / 350

25

055

HONDA iGX800

200

800(L)x550(W)

x765(H)

Senator G2FI

B (9,000 BAR/

LITRES)

JW Triplex 

Plunger

7000 / 500

18

035

HONDA iGX800

200

800(L)x550(W)

x765(H)

Summary of Contents for Senator G2

Page 1: ...uct serial number which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure t...

Page 2: ...ngine Oil 6 Pump Gearbox Oil 6 Wheels 6 Pre Operation Inspection 6 Machine and Work Area Set Up 7 Water Supply 8 Hose Setup 8 Operating Instructions 8 10 Pressure Washer Operation 9 Machine Shut Down...

Page 3: ...t Keep bystanders children and visitors away while operating a pressure cleaner Distractions can cause you to lose control Personal Safety Stay alert watch what you are doing and use common sense when...

Page 4: ...ng equipment Do not eat or smoke while operating or handling high pressure cleaning equipment This will help prevent contamination with toxic or infectious material Do not spray toxic or flammable liq...

Page 5: ...o be used at such high pressure to remove dirt and grime from surfaces The Senator G2 High Pressure Cleaner is equipped with a gasoline HONDA engine to drive the triplex plunger pump Figure 3 Machine...

Page 6: ...eels Axles Locking Collar are found within the box To assemble the wheels slide axles through axle location hole slide wheels on each side find centerline and proceed to install locking collar each si...

Page 7: ...bon monoxide a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows are open Only operat...

Page 8: ...ithout the hose attached to a spray gun Hose can whip causing striking injuries and spray can penetrate skin and cause serious injury High pressure fluid can inject under skin resulting in serious inj...

Page 9: ...is Make sure there is adequate water flow to the unit Turn the unit OFF Remove the nozzle and clean the orifices with the a nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs...

Page 10: ...lowed by positive cable connection 3 Remove battery 4 Reverse procedure to install Replacement batteries should have the following specifications BCI Group Type U1 Size L x W x H 196 x 128 x 159 mm Vo...

Page 11: ...pplicable remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out of the system This can also be used to remove water from the hoses Mac...

Page 12: ...ston packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil se...

Page 13: ...13 SENATOR G2 MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log...

Page 14: ...14 SENATOR G2 MANUAL HIGH PRESSURE CLEANER Notes...

Page 15: ...15 SENATOR G2 MANUAL HIGH PRESSURE CLEANER Notes...

Page 16: ...jetwavegroup jetwave group jetwavegroup 10 16 Smith Street Thebarton 5031 Adelaide South Australia AU 61 8 8371 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group 1300 660 358...

Reviews: