Page 1: ......

Page 2: ......

Page 3: ... occurs within the first 12 months you may return the goods for a full refund or we will repair or replace the goods if you prefer When repair is not practical or identical goods are not available alternative goods of similar specification and quality will usually be provided but failing this you will be offered a partial or full refund depending on the time period since purchase This guarantee sp...

Page 4: ...el pistons chemical injection system adjustable spray nozzle turbo nozzle Every effort has been made to ensure that information in this manual is accurate and current However we reserve the right to change alter or otherwise improve the product and thisdocument at any time without prior notice EQUIPMENT DESCRIPTION SAFETY RULES The label on your tools and manual may show symbols These represent im...

Page 5: ...m the outlet 6 To prevent damage thecord shold notbe crushed placednext to sharpobjects or near a heat source 7 Stay alert watch what you are doing 8 Follow maintenance instructions specified in this manual 9 Check power cords before using Damaged cords can reduce performance of pressure washer or cause a fatal electric shock 10 Keep operating area clear of all persons or animals 11 To reduce the ...

Page 6: ... air circulation the pressurewasher should NOTbe covered during operation 25 Know how to stopthe product andbleed pressure quickly Be thoroughly familiar with the controls 26 Do not over reach or stand on unstable support Keep good footing and balance at all times 27 WARNING Risk of injectionor injury Do not direct discharge streamat persons or animals 28 See page 10 for information on extension c...

Page 7: ...un with high pressure hose 3 Holder for power cable 4 I O switch 5 High pressure hose connector 6 Threaded water inlet 7 Wand with adjustable nozzle 8 Holder for accessories 9 Water plug 10 Screen filter 11 Garden hose inlet nipple ...

Page 8: ... future reference Adjustable Nozzle Attached to nozzle extension Adjustable nozzle allows you to adjust spray pressure and spray pattern Turbo Nozzle Attached to nozzle extension Turbo nozzle is not adjustable and can be used in a variety of applications Use to siphon detergent Chemical Injection Siphon Filter not shown or other pressure washer chemicals into the low pressure stream High Pressure ...

Page 9: ... with the o ring into the high pressure outlet and tightening the threaded nut by hand Fig 1 ASSEMBLY HIGH PRESSURE HOSE WATER CONNECTION Before connecting run water through the garden hose not supplied to flush out any foreign matter Attach garden hose to the pressure washer water inlet connection Fig 2 WATER CONNECTION 11 Fig 1 Fig 2 ...

Page 10: ...t only to a properly earthed outlet ALWAYS use RCD adaptor with this product B Inspect cord before using Do not use if cord is damaged C Keep all connections dry and off the ground D Do not touch plug with wet hands E If replacement of the plug or cord is needed use only identical replacement parts Contact Supplier for proper replacement parts Extension cordsare notrecommended POWER SUPPLY CONNECT...

Page 11: ...tream of water 5 Remove any dirt or foreign matter from the gun outlet and the male connector of the wand 6 Insert the required wand into the gun s quick connect coupling by pushing firmly and twisting the wand 1 4 of a tum to lock into place Fig 4 Make sure wand is locked NOTE Make sure wand is locked NOTE WARNING Fig 3 Fig 4 Do Not Switch the power onto the machine Safety lock locked Safety lock...

Page 12: ... HIGH PRESSURE LOW PRESSURE Fig 6 7 CAUTION Do not adjust the nozzle while the trigger is squeezed The high pressurenozzle positionis intendedfor cleaning When high pressure is required grasp collar and slide the collar and nozzle toward the gun NOTE Make sure the collar is pulled to the extreme rear position towards the gun to lock the nozzle in the high pressure position HIGH PRESSURE LOW PRESSU...

Page 13: ...very powerful and potentially damaging For most cleaning applications a 20 spray angle should be used to avoid damage to the surface being sprayed NOTE The pressure of the spray on the surface you are cleaning increases as you move the wand closer to the surface To increase angle to a fan spray turn counter clockwise ADJUSTABLE SPRAY NOZZLE CAUTION NOTE When low pressure is required grasp collar a...

Page 14: ...ainer of pressure washer detergent and place next to the unit near the injection tube 2 Inspect injection tube filter and ensure that it is not dogged 3 Insert the injection tube into the detergent container and push to the bottom 4 Move adjustable nozzle forward to the low pressure position by sliding collar toward the nozzle The detergent will automotically be mixed with the water and discharged...

Page 15: ...E WETTING THE SURFACE FIRST IS NOT RECOMMENDED AS IT DILUTES THE DETERGENT AND REDUCES ITS CLEANING ABILITY On a vertical surface apply horizontally form side to side starting from the bottom to avoid streaking 2 Allow detergent to remain on the surface for a short time before rinsing CAUTION Damage may occur to painted surface if chemical is allowed to dry on the surface Wash and rinse a small se...

Page 16: ...een is not kept clean the flow of water to the pressure washer will be restricted and the pump may be damaged To clean inner water screen remove quick connect and remove the filter screen from the pump inlet Backflush screen to clean Replace screen and quick connect immediately to prevent any foreign matter from entering the pump NOTE LUBRICATION NOTE WATER SCREEN CAUTION 1 Make sure that the pres...

Page 17: ...l not fall below 0 32 F The pump in this machine is susceptible to permanent damage if frozen DAMAGE CAUSED BY FREEEZING IS NOT COVERED BY THE WARRANTY If you must store your pressure washer in a location where the temperature is below 0 32 F you can minimise the chance of damage to your machine by utilizing the following procedure 1 Stop the pressure washer 2 Squeeze the trigger of the discharge ...

Page 18: ...per extension cord See Operator s Manual section 2 0 Reconnect power plug Allow to cool and restart unit Remove gun aimwater stream away from electrical source and press ON If machine starts gun isdefective Check thatthe circuit is rated15A orgreater Use properextension cord asrecommended in operator smanual section3 3 Cleannozzle as instructedin section 5 2 Clean nozzle as instructed in section 5...