Water Supply

Run a hose from the water source to the unit water inlet.
Use the largest diameter, shortest length hose possible. A 
3/4” I.D. Inlet hose is the minimum recommended size. An 
appropriate backflow prevention device should be used to 
comply with all local codes and ordinances.
Dirt and debris in the water supply can cause excess pump 
wear, clog the unit filter, nozzles and reduce performance.
Do not use water from ponds, lakes or other sources that 
may be contaminated.
Fill the OPTIONAL water tank prior to starting the unit (If 
Applicable).
The OPTIONAL water tank is equipped with a: 
•  Low water level shut-off (If Applicable) to prevent 

pump damage from insufficient water. This will shut 
OFF the engine when the tank water level falls below a 
predetermined level.

•  Float valve to shut-off inlet water when the tank is full, 

preventing water spillage through the tank vent. 

Warm water can be used for improved cleaning. Do not 
use water hotter than 60°C. When using warm water, use 
appropriate personal protective equipment to reduce the 
risk of burns.
When using in cold weather, use precautions to prevent 
water from freezing in the pump. This can damage the 
pump.

Hose Set-Up

Use care when routing hoses. Routing hoses over rough 
surfaces, sharp edges, crossing hoses, etc. can damage 
the hose jacket. Keeping the unit hose on the reel(s) will 
help to minimize hose damage.

Operating Instructions

CAUTION

Always wear eye protection to protect your eyes 
against dirt and other foreign objects. Always wear 
appropriate personal protective equipment for the 
work environment.
Never operate the unit without the hose attached to 
a spray gun. Hose can whip, causing striking injuries 
and spray can penetrate skin and cause serious 
injury.
High pressure fluid can inject under skin resulting 
in serious injury, including amputation. do not direct 
spray at people or animals. do not operate unit above 
pressure rating or 60°C (inlet water temperature). 
This increases the risk of injury, including burns, and 
damage to the unit. One person must control the unit 
process and water flow. 
Always use appropriate personal protective 
equipment while handling and using high pressure 
cleaning equipment. Appropriate personal protective 
equipment always includes safety glasses and 
gloves, and may also include equipment such as latex 
or rubber gloves, face shields, goggles, protective 
clothing, respirators, and steel toed footwear.
Follow operating instructions to reduce the risk of 
injury from whipping hoses, high pressure liquid 
injection, carbon monoxide and other causes.

1.  Make sure that machine and work area is properly set 

up and that the work area is free of bystanders and 
other distractions. If the unit is located remotely from 
the point of use, another person may be located at the 
unit.

2.  Attach the gun to the high pressure hose via coupling 

system.

3.  Attach the hose to the high pressure outlet on the front 

of the unit.

4.  Turn the battery isolator switch ON (Figure 11) and 

confirm the Emergency stop button is in the out 
position (rotate button clockwise). 

5.  Attach your water supply hose to the low pressure 

water inlet port on the front of the machine. Confirm 
that the water supply is turned. Never start the engine 
without the water supply turned ON. This can damage 
the pump.

6.  Ensure fuel valve is in the OPEN position before 

starting the machine, when not in use CLOSE the fuel 
valve as pictured (Figure 11).

Figure.6 - Senator G2 Bypass Tank

Summary of Contents for Senator G2

Page 1: ...uct serial number which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure t...

Page 2: ...ngine Oil 6 Pump Gearbox Oil 6 Wheels 6 Pre Operation Inspection 6 Machine and Work Area Set Up 7 Water Supply 8 Hose Setup 8 Operating Instructions 8 10 Pressure Washer Operation 9 Machine Shut Down...

Page 3: ...t Keep bystanders children and visitors away while operating a pressure cleaner Distractions can cause you to lose control Personal Safety Stay alert watch what you are doing and use common sense when...

Page 4: ...ng equipment Do not eat or smoke while operating or handling high pressure cleaning equipment This will help prevent contamination with toxic or infectious material Do not spray toxic or flammable liq...

Page 5: ...o be used at such high pressure to remove dirt and grime from surfaces The Senator G2 High Pressure Cleaner is equipped with a gasoline HONDA engine to drive the triplex plunger pump Figure 3 Machine...

Page 6: ...eels Axles Locking Collar are found within the box To assemble the wheels slide axles through axle location hole slide wheels on each side find centerline and proceed to install locking collar each si...

Page 7: ...bon monoxide a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows are open Only operat...

Page 8: ...ithout the hose attached to a spray gun Hose can whip causing striking injuries and spray can penetrate skin and cause serious injury High pressure fluid can inject under skin resulting in serious inj...

Page 9: ...is Make sure there is adequate water flow to the unit Turn the unit OFF Remove the nozzle and clean the orifices with the a nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs...

Page 10: ...lowed by positive cable connection 3 Remove battery 4 Reverse procedure to install Replacement batteries should have the following specifications BCI Group Type U1 Size L x W x H 196 x 128 x 159 mm Vo...

Page 11: ...pplicable remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out of the system This can also be used to remove water from the hoses Mac...

Page 12: ...ston packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil se...

Page 13: ...13 SENATOR G2 MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log...

Page 14: ...14 SENATOR G2 MANUAL HIGH PRESSURE CLEANER Notes...

Page 15: ...15 SENATOR G2 MANUAL HIGH PRESSURE CLEANER Notes...