background image

JE-900 series PTZ Camera 

 

Operation Guider 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for JE-900 series

Page 1: ...JE 900 series PTZ Camera Operation Guider ...

Page 2: ...I Connecting diagram 1 1 For the high speed dome camera with alarm function JE 900H 1 2 For the low spped dome camera without alarm function JE 900L IR800 ...

Page 3: ...storage and accurate locating 8 4 tour groups 16 preset positions can be stored in each tour group 9 Support Left Right scan function Low Medium and High 3 levels speeds optional 10 The unit has a default position 11 4 channels alarm in 1 channel alarm out 12 Pan 360 consecutive movement no blind area for the monitoring 13 Tilt 90 auto flip at the bottom which ensures consecutive monitoring 14 Aut...

Page 4: ...60 161 is special for low speed camera 3 Code 165 166 and 95 is for special order 4 above code is fixed and stored in the camera you must enter the code number and key preview some controller named invoke call or function key on controller for its function The code on the above table is the important details for operation the camera 3 1 Setup and Preview Preset Positions The camera can store the c...

Page 5: ...mple Preview Preset position No 2 a Enter 2 b Press the PREVIEW key The camera will go to the preset 2 immediately 3 2 Setup and running of Tour group User can program the preset positions into the automatic tour in the required order when necessary run the tour group the camera will automatically scan the preset positions set in the tour consecutively and circularly Up to 16 preset positions can ...

Page 6: ...r the dome camera will be in order of 1 2 5 3 4 6 to scan Dwell time and more one tour groups setup please refer the controller menu to do 3 3 Setup and scan between two points The user can freely set a beginning point as the Left Limiting Position an end point as the Right Limiting Position Meanwhile the user can also set the zoom times on the position the camera only store the parameters on the ...

Page 7: ...ium speed 3 Key 134 Preview on controller the camera will scan between two points with high speed 3 4 Start 360 scanning function of the Pan Tilt The Camera can be 360 endless horizontal scanning for all direction monitoring Three speeds can be optional 135 for low speed 136 for medium speed 137 for high speed 3 5 Setup Activate and Exit Default Position The unit has a default position The user ca...

Page 8: ...wing With the alarm function the camera auto tours up to 4 areas where need to motion once the one of alarm sensors is triggered the camera will rapid run and stay toward the where motion detected Alarm output connection sketch Connection sketch for Alarm input with Usual closed detector ...

Page 9: ...rm 1 Setup preset position 2 for alarm 2 Setup preset position 3 for alarm 3 Setup preset position 4 for alarm 4 Step 2 Setup an alarm cruising group All alarm preset positions preset position 1 4 must setup in the same group Step 3 Running alarm tour Enter 142 preview on keyboard controller to start the alarm preset cruising Step 4 Run and exit alarm system ...

Page 10: ... is needed to restore Scan Cruising etc functions c Whether the alarm function is enabled or not the alarm output always responds For example under the alarm function is inactive mode the camera will not move to the position alarm triggered but the alarm output still responds e A 2 2KΩ resistor must be connecting for the channel without detector otherwise the camera will thinks that there is alarm...

Page 11: ...ra ID and baud rate SW2 6 bit switches for setup protocol the setup diagram is as below Camera ID Setting Chart No 654321 No 654321 No 654321 No 654321 1 000001 18 010010 35 100011 52 110100 2 000010 19 010011 36 100100 53 110101 3 000011 20 010100 37 100101 54 110110 4 000100 21 010101 38 100110 55 110111 5 000101 22 010110 39 100111 56 111000 6 000110 23 010111 40 101000 57 111001 7 000111 24 01...

Page 12: ...nside cover SW1 8 bit switches for setup the camera ID and baud rate SW2 4 bit switches for setup protocol 1 2 and Baud Rate 3 4 The setup diagram is as below Camera ID Setting Chart 1 93 No 87654321 No 87654321 No 87654321 1 00000001 32 00100000 63 00111111 2 00000010 33 00100001 64 01000000 3 00000011 34 00100010 65 01000001 4 00000100 35 00100011 66 01000010 5 00000101 36 00100100 67 01000011 6...

Page 13: ...0101 24 00011000 55 00110111 86 01010110 25 00011001 56 00111000 87 01010111 26 00011010 57 00111001 88 01011000 27 00011011 58 00111010 89 01011001 28 00011100 59 00111011 90 01011010 29 00011101 60 00111100 91 01011011 30 00011110 61 00111101 92 01011100 31 00011111 62 00111110 93 01011101 V Specification 5 1 High Speed Dome Pan Tilt Pan speed Manual control 0 5º 200º s 64 ranges Max Speed 400 s...

Page 14: ...ra address range 1 255 Alarm 4 Channels in 1 Channel out Fog Dispersion function Optional Fan Heater Working range 50 º C or 5 º C 5 2 Low Speed Dome Pan Tilt Highest Pan speed 20 s Pan speed 5 20 s Pan Tilt movement 360 endless 90 Preset Position 64 Cruise Tracking Group 4 groups 16 preset positions in each Scan Speed High Medium Low 3 levels optional Default Position function Yes Scan between 2 ...

Page 15: ...k RS485 bus connection Abnormal self check image with motor noise Mechanical failure Repair Camera inclined Reinstall Power supply not enough Replace better to place the adaptor nearby the speed dome Unstable image Bad connection of video cable Correct Power supply not enough Replace Fuzzy image At Manual focus state Operate the dome camera or preview any preset positions Vitreous cover dirty Clea...