Jetter AG
Technical specifications | 4
JXM-IO-E32 User Manual
14 / 38
Category
Description
Input frequency
0.1 Hz ... 10 kHz
Dielectric strength
Max. +32 V
Tab. 10:
Digital inputs DI_1 ... DI_6
Configuration in-
puts
Configuration inputs are tristate inputs and are used to set the node ID. The base
address can be set via SDO and has the default value 0x50. The node ID can be
shifted by connecting the configuration inputs with VBAT_ECU or GND via an off-
set.
Category
Description
Configuration inputs for configuring the node ID
Abbreviation
CFG1_IN
CFG2_OUT
Quantity
2
Tab. 11:
Configuration inputs CFG1_IN … CFG2_OUT
For more information refer to chapter
4.7 Outputs
Analog outputs
Category
Description
Analog output
Abbreviation
AO
Quantity
3 pcs.
Mode
0 … 20 mA
or
0 … 10 V: 20 mA max.
It is possible to switch
between the configura-
tion as current output or
voltage output.
Accuracy (current)
+/-2.5 % of the value
range
Accuracy (voltage)
100 mV
Resolution
12 bits configured in mV
Tab. 12:
Outputs AO_1 ... AO_3
Outputs VREF_10V
Category
Description
Abbreviation
VREF_10V
Quantity
2 pcs.
Operating voltage
10 V
Accuracy
1%
Operating current
Min. 100 mA
Accuracy
1%
Diagnostic functions
The voltage generated at
the 10 V power supply
can be read out via
SDO. Each channel can
be checked for short cir-
cuit.
Tab. 13:
VREF_10V