7 Description of Connections
70
Jetter AG
LinMot Encoder Cable
JetMove 108
(male SUB-D connector
X61)
Shield
Cable specification
Maximum cable length:
25 m
Attaching screws must
have a metric thread!
Connect shield with the
greatest possible surface
area!
Use metallized housing
only!
Pin
Signal
Core Color
5
Sine
amber
4
Cosine
green
1
Voltage output
(5 volts)
white
11
0 V
inner shield
Shield
Shielding
outer shield
1
6
11
5
10
15
Shield
Note 1!
Supply v5 V at the JetMove 108:
Due to conduction loss, a lower voltage might be supplied to the encoder.
Note 2!
The LinMotor motor cable features double shielding. Do not connect both
shields with each other. The inner shield is used as 0 V line. Connect it to
0 V signals only! The outer shield must be connected to the shielding
terminal of the Sub-D connector.