Grey Water Interface Unit 12L

Tel. +47 70 03 91 00

www.jetsgroup.com

Product No. GWT800PL

Doc. Rev.: 2 (2019-06-17)

1

Jets™ Grey Water Interface Unit consists of a tank fitted with a level 
switch and a discharge valve.  Grey water is led to the tank by gravity 
and interfaced with the vacuum system via the valve.  The valve is 
activated by the water level inside the tank.

Technical Data

........................................

Tank Type

Interface Unit/Buffer Tank Assembly

..................................

Outside Dimensions

400 x 200 x 473 mm (LxWxH)

.................................................................................

Weight

Approx.  4 kg

..................................................................................

Generic Material

PE

....................................................................................

Color Range

White

...............................................................................

Tank Volume

12 Litres

...........................................

Discharge Volume

4 Litres at 30% Vacuum

4.5 Litres at 55% Vacuum

............................................................................

Inlet

Diameter - Ø50mm

..................................

Discharge Valve Outlet

Outside diameter Ø 50 mm

.....................

Note:

Values may vary depending on selected components

Disclaimer

Note: Our products and services are offered and sold subject to Jets 
Vacuum AS’ General Sales Conditions, copies of which will be 
furnished upon request. Information provided herein is solely for 
information purposes, does not constitute any warranty or 
representation of any kind and is subject to change without notice. 
We strive to reproduce product colors reasonably accurate. Without 
prior written approval, this document or any part of may not be 
reproduced in any form. Jets™, Vacuumarator™, Helivac™, VC™, 
VOD™, CVS™ and Softsound™ are trademarks and/or registered 
trademarks of Jets. © Jets AS. All rights reserved.

Components

1

Grey Water Tank 12L, plastic ....................................

080500026*

2

Tank/Pipe Seal, ø50mm ............................................

034505310*

3

Pipe Bend, ø50mm 90dg ..........................................

034512584*

4

Suction Pipe ..............................................................

034512700*

5

Bracket ......................................................................

010100750*

6

Screw, 4x20 ..............................................................

036515607*

7

Screw, M5x10 ...........................................................

036531600*

8

Nut, M5 .....................................................................

036304802*

9

VD Valve, Piston Complete .......................................

054100955*

10

Level Switch ...............................................

see product selection

* Component/s avaliable as replacement parts.

Accessories

Construction Characteristics

Rubber Elbow, ø50 w/Hose Clip.............................................

034505450

Rubber Sleeve, ø50 w/Hose Clip...........................................

034505550

Air/Overflow Valve, Complete.................................................

035202511

Level Switch...........................................................................

032803900

Rubber Elbow, ø50/ø60 w/Hose Clip.....................................

034512802

Rubber Sleeve, ø50/ø60 w/Hose Clip....................................

034512902

Summary of Contents for GWT800PL

Page 1: ...d upon request Information provided herein is solely for information purposes does not constitute any warranty or representation of any kind and is subject to change without notice We strive to reproduce product colors reasonably accurate Without prior written approval this document or any part of may not be reproduced in any form Jets Vacuumarator Helivac VC VOD CVS and Softsound are trademarks a...

Page 2: ...G 100mm H 200mm I 45mm J 45mm K Ø50 L 15mm M 170mm N 9mm O 20mm A 470mm Note Installation is to occur within the water barrier in line with local industry requirements and in compliance with all local state and federal wet room requirements Note the Air Overflow Valve shown in the dimension drawing may not be included in the tank delivery but may be purchased as an accessory ...

Page 3: ...sing Sequence 1 Level Sensor ℱ DEACTIVATES 2 Controller ℰ DEACTIVATES 3 Valve ℯ CLOSES 4 Suction Pipe EMPTIES 5 Outlet C FLOW STOPS Result Grey water enters the tank until the determined level is reached Grey water is sucked from the tank to the outlet Chemicals and Detergents The following information is for Grey Water Interface Units which have washing machines kitchen sinks showers etc connecte...

Page 4: ...anding by that can render aid if needed If extended periods of time are required for tank inspections repairs appropriate respiratory equipment PPE should be utilized 9 2 Danger Disease Hazards Effluent is a common mode of transmission for parasitic organisms Some of these may be pathogenic meaning that they may have the capability of causing serious communicable disease Good personal hygiene use ...

Page 5: ... A Interchangable connection for the Inlet gravity inlet from the source Air Overflow Note that an air overflow valve is required A suitable valve is available in Jets product range Alternatively the tank may be vented for example above roof height B Outlet Optional C For installations with LAH Level Alarm High D For installations with a VTS VIP Controller Refer to the tanks technical information ...

Page 6: ...t routine inspection and cleaning inside and outside of the tank be carried out a minimum of one time each third year depending on frequency of use Service and Maintenance Technical Assistance Jets Vacuum AS provides all customers with 24 hour worldwide technical assistance For urgent matters please contact Jets Vacuum AS service department directly at 47 70039100 For other matters please contact ...

Page 7: ...Cause Action Tank content is not discharged No vacuum Check sufficient vacuum is being generated Discharge time is too short Increase the discharge time up to a Maximum of 2 seconds after the tank is empty Valve is blocked due to debris Remove the debris Defective non return valve Clean or replace the non return valve Leaks in the vacuum hose s on the valve Replace the hose s or check that hose s ...

Reviews: