background image

Grey Water Interface Unit 12L

Tel. +47 70 03 91 00

www.jetsgroup.com

Product No. GWT800PL

Doc. Rev.: 2 (2019-06-17)

4

Important Health and Safety Information

Installation, operation and maintenance must be carried out in strict accordance with this guide and with all applicable regulations. For your own 
protection and the protection of others, it is necessary to familiarize yourself with, and always follow, the contained safety and environmental 
precautions for our products.

This manual is an integral part of the product/delivery. Always keep it in a safe place for future reference. It is entirely the owner’s responsibility to 
ensure that all safety and environmental measures, in accordance with local, state and federal laws are followed. Jets Vacuum AS assumes no 
responsibility for equipment damage, personal injury or death and/or delays that result from a lack of respect for the instructions for installation 
and/or use as stated in this documentation. Disregarding these instructions may invalidate all warranties.

Safety information references are in accordance with Jets Vacuum AS documentation system. If you do not understand the warnings, stop work 
immediately and contact Jets Vacuum AS (citing the safety reference number) for further clarification. 

For further information about the included warnings or any other safety concerns please contact Jets Vacuum AS.

Important Health and Safety Warnings

1.1 Warning

Jets Vacuum AS recommend qualified person(s) in accordance with all applicable 
codes and standards to carry out all installation work, electrical wiring, plumbing and 
operate this product. Equipment damage, injury to personnel or death could result 
from improper installation/use. 

1.2 Warning

Be thoroughly familiar with the controls and the proper use of the equipment prior 
to installing, starting or using the equipment. Know the equipment application, 
limitations and potential hazards.

1.4 Caution

Safety equipment (PPE) necessary for the prevention of accidents at the 
installation and operating site must be provided in accordance with local 
regulations.

1.5 Personal Protective Equipment - Goggles

Wear safety glasses with side shields at all times when working with equipment.

1.9 Personal Protective Equipment - Gloves

Wear suitable protective gloves at all times when working with equipment.

2.6 Notice

Place the equipment in an area that is easily accessible for maintenance.

9.1 Danger

Gas Hazards: Putrefied organic matter will produce disagreeable odors and an 
oxygen deficient atmosphere. During service of tanks, sufficient exterior air 
must ventilate the tank to counteract the oxygen deficient environment prior to 
service being carried out. Under no circumstances should a person service the 
tank without a second person standing by that can render aid if needed. If 
extended periods of time are required for tank inspections/repairs, appropriate 
respiratory equipment (PPE) should be utilized.

9.2 Danger

Disease Hazards: Effluent is a common mode of transmission for parasitic 
organisms. Some of these may be pathogenic, meaning that they may 
have the capability of causing serious communicable disease. Good 
personal hygiene, use of disinfectant soap and avoidance of hand to 
mouth transfer are necessary for all working in contact with the 
equipment. Skin abrasions, punctures or wounds of any other nature 
require immediate and proper medical attention. 

9.8 Warning

Avoid breathing in dust from grey water. 

12.5 Notice

Use this equipment only in the manner intended by Jets Vacuum AS. If you have 
questions after reading these instructions contact Jets Vacuum AS directly.

12.7 Notice

Additional and replacement parts should only be obtained from the manufacturer or 
distributor.

2.13 Caution

Installation, service and maintenance are to be carried out with due care. Shock, 
innapropriate handling, incorrect use of tools and general mishandling of the 
product may result in damage to components.  

10.5 Notice

Chemical detergents, when used excessively, may result in foaming in discharge from 
the Vacuumarator™ pump. 

Delivery, Receipt of Goods and Transportation

Goods to be protected against shock and damage. Suitable adequately dimensioned transporting equipment is to be used. Note that the 
equipment may contain components that are easily damaged as a result of inappropriate handling. Jets Vacuum AS is not responsible for or liable 
for delivery delays resulting from occurrences outside of Jets Vacuum AS' immediate control. On receipt of goods, check for visual damage. Any 
damage detected after dispatch should be reported immediately to Jets Vacuum AS. Damages and/or discrepancies must be reported in writing no 
later than eight (8) days after receipt of goods. Commissioning must be postponed until the equipment has been inspected. Do not dispose of 
damaged items. Your direct supplier will advise you of the procedure to follow.

Storage

Unless otherwise specified, goods are to be stored in a dry environment between -30°C and +40°C prior to installation. The storage location must 
be dust free, low humidity (≤95%) and be free from moisture. Keep clear of foreign objects.

Installation to End Use

Site to be a dry environment b0°C and +60°C. Use in environments below 0°C requires use of antifreeze in liquids. The site location is to 
be low vibration Vrms ˂0.2 mm/s) with vibration resistance to acceleration up to 0.7g. The site is to be dust free and protected from grinding and 
welding. Goods are to be stored as per the instructions for delivery, storage and transport. A visual inspection is to carried out on receipt of goods
as well as at the time of installation to ensure that storage and transport conditions after receipt have not compromised the quality of the product/s. 

Summary of Contents for GWT800PL

Page 1: ...d upon request Information provided herein is solely for information purposes does not constitute any warranty or representation of any kind and is subject to change without notice We strive to reproduce product colors reasonably accurate Without prior written approval this document or any part of may not be reproduced in any form Jets Vacuumarator Helivac VC VOD CVS and Softsound are trademarks a...

Page 2: ...G 100mm H 200mm I 45mm J 45mm K Ø50 L 15mm M 170mm N 9mm O 20mm A 470mm Note Installation is to occur within the water barrier in line with local industry requirements and in compliance with all local state and federal wet room requirements Note the Air Overflow Valve shown in the dimension drawing may not be included in the tank delivery but may be purchased as an accessory ...

Page 3: ...sing Sequence 1 Level Sensor ℱ DEACTIVATES 2 Controller ℰ DEACTIVATES 3 Valve ℯ CLOSES 4 Suction Pipe EMPTIES 5 Outlet C FLOW STOPS Result Grey water enters the tank until the determined level is reached Grey water is sucked from the tank to the outlet Chemicals and Detergents The following information is for Grey Water Interface Units which have washing machines kitchen sinks showers etc connecte...

Page 4: ...anding by that can render aid if needed If extended periods of time are required for tank inspections repairs appropriate respiratory equipment PPE should be utilized 9 2 Danger Disease Hazards Effluent is a common mode of transmission for parasitic organisms Some of these may be pathogenic meaning that they may have the capability of causing serious communicable disease Good personal hygiene use ...

Page 5: ... A Interchangable connection for the Inlet gravity inlet from the source Air Overflow Note that an air overflow valve is required A suitable valve is available in Jets product range Alternatively the tank may be vented for example above roof height B Outlet Optional C For installations with LAH Level Alarm High D For installations with a VTS VIP Controller Refer to the tanks technical information ...

Page 6: ...t routine inspection and cleaning inside and outside of the tank be carried out a minimum of one time each third year depending on frequency of use Service and Maintenance Technical Assistance Jets Vacuum AS provides all customers with 24 hour worldwide technical assistance For urgent matters please contact Jets Vacuum AS service department directly at 47 70039100 For other matters please contact ...

Page 7: ...Cause Action Tank content is not discharged No vacuum Check sufficient vacuum is being generated Discharge time is too short Increase the discharge time up to a Maximum of 2 seconds after the tank is empty Valve is blocked due to debris Remove the debris Defective non return valve Clean or replace the non return valve Leaks in the vacuum hose s on the valve Replace the hose s or check that hose s ...

Reviews: