Service and Maintenance
Out of Use - Not in Regular Use
The following procedures are to be followed if a toilet is to be out of use over a longer period of time (i.e for cabins and recreational houses).
1. Close the water supply valve.
2. Run a flush cycle by activating the release mechanism.
3. Close the toilet seat cover.
4. CAUTION: This toilet is not intended for use in temperatures below freezing without appropriate antifreeze measures being taken. For
locations where frost/freezing may occur, frost protection measures must be taken. For further information contact Jets Vacuum AS or your
nearest supplier for a copy of technical information regarding frost protection measures.
5. CAUTION: Never use automotive antifreeze (ethylene glycol) in the toilet system.
6. Turn off the power.
NOTE: Failure to adequately protect the toilet system from damages may result in void of your warranty coverage.
NOTE: Jets Vacuum AS reserves the right to deny any warranty claim submitted if the claim is caused by frost/freezing damage.
Cleaning Instructions
1. Mild soap or biological cleaners are recommended for cleaning the toilet. See Jets Vacuum AS product range for suitable cleaning solutions.
2. Do not use cleaners that create foam.
3. The toilet is to be cleaned regularly to maintain hygiene.
4. Do not use caustic cleaners (such as drain cleaner) or bleach. These products may damage components in the toilet system.
5. If using abrasive, chlorine or corrosive cleaners, avoid contact with the seat and cover/hinges.
6. For scale buildup, we recommend use of Jets Vacuum AS biological descale products. Contact your Jets Vacuum AS supplier for information.
7. Note that maintaining water in the toilet bowl will prevent odors.
Spare Parts and Accessories
Available spare parts are indicated in the component list for the toilet. Spare parts and accessories can be ordered via your local Jets Vacuum AS
supplier. For multi-toilet installations, a complete recommendation for spare parts is available. Contact your Jets Vacuum AS supplier for details.
Service and Maintenance
Jets Vacuum AS provides all customers with 24 hour worldwide technical assistance. For urgent matters please contact Jets Vacuum AS service
department directly at +47 70039100. For other matters, please contact your nearest Jets Vacuum AS supplier.
1. Disassembly of the toilet must be carried out by a licensed professional.
2. All local, state and fedral regulations regarding water barriers and plumbing must be adhered to.
3. Disassembly of components may void the warranty.
4. Refer to the technical data sheets for specific product information. Refer to the products troubleshooting information for general maintenance.
5. It is recommended that service and maintenance routines be carried out in accordance with the information in this document.
When making enquiries, please have the following information available.
1. Toilet model number.
2. For valve enquiries: Valve serial number (the serial number identification is located on the label applied to the valve).
3. Part number, description, quantity (see the product component list for details).
Locating a Water Leak
To locate the source of a water leak, first thoroughly dry all surfaces. Leaks at room temperature can make it difficult to feel wetness. Using a piece
of soft tissue pat the surface. When the tissue comes in contact with water it will immediately change texture.