background image

Jets™ Charm Toilet 

Tel. +47 70 03 91 00
www.jetsgroup.com

Product No. TO611PO

Issued 2013-10-28 Rev 3.0

Service and Maintenance

Out of Use - Not in Regular Use

The following procedures are to be followed if a toilet is to be out of use over a longer period of time (i.e for cabins and recreational houses).

1. Close the water supply valve.

2. Run a flush cycle by activating the release mechanism.

3. Close the toilet seat cover.

4. CAUTION: This toilet is not intended for use in temperatures below freezing without appropriate antifreeze measures being taken. For 

locations where frost/freezing may occur, frost protection measures must be taken. For further information contact Jets Vacuum AS or your 
nearest supplier for a copy of technical information regarding frost protection measures.

5. CAUTION: Never use automotive antifreeze (ethylene glycol) in the toilet system.

6. Turn off the power.

NOTE: Failure to adequately protect the toilet system from damages may result in void of your warranty coverage. 

NOTE: Jets Vacuum AS reserves the right to deny any warranty claim submitted if the claim is caused by frost/freezing damage.

Cleaning Instructions

1. Mild soap or biological cleaners are recommended for cleaning the toilet. See Jets Vacuum AS product range for suitable cleaning solutions.

2. Do not use cleaners that create foam.

3. The toilet is to be cleaned regularly to maintain hygiene.

4. Do not use caustic cleaners (such as drain cleaner) or bleach. These products may damage components in the toilet system.

5. If using abrasive, chlorine or corrosive cleaners, avoid contact with the seat and cover/hinges.

6. For scale buildup, we recommend use of Jets Vacuum AS biological descale products. Contact your Jets Vacuum AS supplier for information.

7. Note that maintaining water in the toilet bowl will prevent odors.

Spare Parts and Accessories

Available spare parts are indicated in the component list for the toilet. Spare parts and accessories can be ordered via your local Jets Vacuum AS 
supplier. For multi-toilet installations, a complete recommendation for spare parts is available. Contact your Jets Vacuum AS supplier for details. 

Service and Maintenance

Jets Vacuum AS provides all customers with 24 hour worldwide technical assistance. For urgent  matters please contact Jets Vacuum AS service 
department directly at +47 70039100. For other matters, please contact your nearest Jets Vacuum AS supplier. 

1. Disassembly of the toilet must be carried out by a licensed professional.  

2. All local, state and fedral regulations regarding water barriers and plumbing must be adhered to. 

3. Disassembly of components may void the warranty. 

4. Refer to the technical data sheets for specific product information. Refer to the products troubleshooting information for general maintenance. 

5. It is recommended that service and maintenance routines be carried out in accordance with the information in this document.

When making enquiries, please have the following information available. 

1. Toilet model number.

2. For valve enquiries: Valve serial number (the serial number identification is located on the label applied to the valve).

3. Part number, description, quantity (see the product component list for details).

Locating a Water Leak

To locate the source of a water leak, first thoroughly dry all surfaces. Leaks at room temperature can make it difficult to feel wetness. Using a piece 
of soft tissue pat the surface. When the tissue comes in contact with water it will immediately change texture.

Summary of Contents for Charm

Page 1: ... 50 Vacuum Water Consumption 1 liter s 3 bar adjustable Note Values are dependent on product selection Patents and Trademarks Jets Vacuumarator Helivac VC VOD CVS and Softsound are trademarks and or registered trademarks of Jets Copyright 2011 Jets AS Disclaimer Product color reproduction is as near to actual color as product methods allow All rights reserved Information is subject to change witho...

Page 2: ...ces eyebolts slings spreaders etc must be rated selected and used for the entire load being lifted 1 4 Warning Safety equipment PPE necessary for the prevention of accidents at the installation and operating site must be provided in accordance with local regulations 1 5 Personal Protective Equipment Goggles Wear safety glasses with side shields at all times when working with equipment 1 6 Warning ...

Page 3: ...structed prior to installation of the toilet Connection with Pressurized Mains Water To connect pressurized water i e mains water to the toilet the water pipe must be installed The connection required is a 1 2 BSP standard connection The water pressure must be a minimum of 1 8kp 2 bar and must not exceed 7 bar Installation Instructions Toilet installation requires the following procedures to be ca...

Page 4: ...emoving the bowl from the wall fixture no maintenance cavity is required behind the wall 400mm Toilet Height Seat height is variable It is recommended that the top of the toilet bowl be installed at a height of 400mm from the floor surface for standard installations 1 Prepare the Wall Mounting Prepare the wall mounting as per the instructions above Note that the toilet may be mounted on appropriat...

Page 5: ... 11 Note that an M12 nut is required to secure the toilet not supplied in the standard delivery Secure the nut firmly without over tightening 12 Completed 13 Function Check to be Completed Prior to Use 1 Clean the bottom of the bowl 2 Ensure that the discharge valve has been securely connected to the outlet pipe 3 Check that the water supply is connected and water pressure is adequate 4 Turn on th...

Page 6: ...use of Jets Vacuum AS biological descale products Contact your Jets Vacuum AS supplier for information 7 Note that maintaining water in the toilet bowl will prevent odors Spare Parts and Accessories Available spare parts are indicated in the component list for the toilet Spare parts and accessories can be ordered via your local Jets Vacuum AS supplier For multi toilet installations a complete reco...

Page 7: ...ed equipment including the valve pump etc for foreign objects Remove any blockages in the system Check the pipe system to ensure there is no air entering the pipes damage to the pipe system The normal water level in the toilet bowl is reducing low Low water pressure Increase the water pressure Check the filter in the water connection ball valve to ensure that it is not blocked Replace the filter i...

Reviews: