s parameter Esc(s#1,#2,#3,#4s
1-D BARCODES:
Space Widths
#1,
space width, first (thin) width in dots (1/600 inch)
#2,
space width, second width in dots (1/600 inch)
#3,
space width, third width in dots (1/600 inch)
#4,
space width, fourth width in dots (1/600 inch)
Example: Thin spaces 4 dots, thick spaces 8 dots : 4,8s
Note:
the b parameters can be sent alone if the
b
and
s
parameters are identical. It allows
to send shorter PCL barcoding commands to the printer.
2-D BARCODES:
PDF417: Symbol format parameters
#1,
Symbol black/white module height compared to the width (1 to 10).
Unit=minimum module width (default=3)
#2,
X parameter for the symbol X/Y size ratio (default: 2 for 2/3)
#3,
Y parameter for the symbol X/Y size ratio (default: 3 for 2/3)
#4,
Symbol module min width (1 to 100).
Unit=1/100 inch (default value=10).
The width value triggers a predefined scaling of the base barcode.
Example: square PDF, minimum module width, smaller module size : 1,1,1,5s
QRCode:
#1: Symbol set for input data
0
Use default (Automatic: JIS/ShiftJIS)
1
Numeric (0to9)
2
Alphanumeric (0to9, uppercase A to Z, space $%*+-. /: )
3
Binary 8-bits/byte data (JIS 8-bit character set (Latin and Kana)
in accordance with JISX0201)
4
Kanji characters (Shift JIS values 8140h to 9FFCh and E040h
to EAA4h shifted from JIS X0208)
Example: QRCode, alphanumeric data: 2s
OMR: