Instructions manual: MULi6s Module

3. MULi6s Module sensor connection options:

1.

The MULi6s  Module three-wire sensor cable with the JR connector can be connected directly to
the JETIBOX (connector labeled I -). Use the second JETIBOX input, which is marked
(+ -), to bring the supply voltage. This connection does not use wireless data transmission and the
measured values are displayed directly on the JETIBOX LCD. This connection does not allow the
generation of alarms because the siren is part of a transmitter module that is not connected in this
case. Alarms are only displayed on the LCD.

2.

Connect the 3-wire MULi6s Module sensor cable with the JR connector to the DUPLEX receiver
connector on the rear (marked Ext.). The MULi6s  Module  sensor is powered from the receiver.
To set the MULi6s  Module  sensor parameters, connect the JETIBOX to the transmitter module
and turn on the DUPLEX receiver and transmitter. You can also set this sensor using the Jeti DC /
DS transmitter in Menu / Model / Device Explorer.

Incorrect connection procedure:

 The module connects to the disconnected receiver or the Jetibox and

the battery is connected.

6

Summary of Contents for MULi6s EX

Page 1: ...INSTRUCTIONS FOR USING SENSOR MULI6S MODULE Producer JETI model s r o 14 12 2017...

Page 2: ...6s Module SENSOR CONNECTION OPTION 6 3 1 Jetibox 6 3 2 Receiver 6 4 MENU JETIBOX 7 4 1 Actual values 7 4 2 Min Max 8 4 3 Settings 8 4 4 Alarms 8 4 5 Service 8 5 CONFIGURATION USING A DC DS TRANSMITTER...

Page 3: ...sor connection Muli6s Module Notice Try to follow the following connection procedure 1 Connect the MULi6s Module sensor to the Li XX battery connector Make sure the connector polarity is correct 2 Con...

Page 4: ...go out after a while Then the LED always lights for 0 3s and displays the state of the weakest cell to save the potential of the first two cells To put the module back into sleep mode just unplug the...

Page 5: ...Instructions manual MULi6s Module Notice Only use wires that are part of the sensor for serial connection of modules 5...

Page 6: ...s because the siren is part of a transmitter module that is not connected in this case Alarms are only displayed on the LCD 2 Connect the 3 wire MULi6s Module sensor cable with the JR connector to the...

Page 7: ...ead data When connected to the MULi6s Module a startup screen appears which contains the sensor identification and the number of connected battery cells on the first row of the sensors of all connecte...

Page 8: ...minimum and maximum will be reset when the sensor is switched on for the first time 4 4 MULi6s Module MENU ALARMS Press the D Down Arrow button to enter the individual alarm settings If a set paramet...

Page 9: ...will go to the configuration menu Reset to factory defaults to retrieve the default MULi6s Module setting 5 1 Telemetry Total voltage shows the current total battery voltage and the number of all con...

Page 10: ...kest and strongest cells throughout the flight In addition to the voltage which of the two cells this difference affects the first number corresponds to the strongest cell MIN MAX Telemetry of all cel...

Page 11: ...Consumption 70uA Maximum of connected modules 5 Number of batteries connected to one module 1 Maximum number of cells connected to one module 6 Maximum voltage on one module 26 4V 8 Guarantee The prod...

Page 12: ...Instructions manual MULi6s Module MULi6s Module menu displayed on JETIBOX terminal 12...