Instructions manual: MULi6s Module

4.2.

MULi6s Module MENU: MIN / MAX

 - Press D (Down Arrow) to select the display of the 

voltage extremes recorded during the measurement. Extreme recording is automatically deleted 
according to the trigger settings in the "Settings" menu or can be deleted manually.

Reset Min / Max

 - simultaneously pressing the R and L arrows (right and left) deletes the record of 

the measured minimum and maximum parameters.

Weakest Cell

 - Featuring the weakest cell for the entire flight - its voltage and cell number.

Total Volt MIN / MAX

 - Shows the minimum and maximum total battery voltage measured over the

entire flight.

MAX Difference

 - Displays the greatest voltage difference between the weakest and strongest cells 

throughout the flight. In addition to the voltage, which of the two cells this difference affects, the first 
number corresponds to the strongest cell.

Cell MIN MAX 

- Displays the minimum and maximum voltages of the currently selected cell. Use R

and L to select the cell number that we want to view.

4.3.

MULi6s Module MENU MODE: SETTINGS

 - Press D (down arrow) to enter the basic setting 

of the sensor.

Min Max Trigger

 - Set the voltage value for which the minimum and maximum will be reset when

the sensor is switched on for the first time.

4.4.

MULi6s Module MENU: ALARMS

 - Press the D (Down Arrow) button to enter the  individual

alarm settings. If a set parameter is exceeded, then the JETIBOX LCD in the main menu on the 
second line will alternately display the original display with the corresponding alarm, while the 
red LED will illuminate at the time of the alarm display. If the alarm is set to "Off", the alarm is 
off. If multiple alarms occur at the same time, they are displayed on the second line of the 
JETIBOX.

Total Voltage Alarm

 - Low battery alarm setting. If the measured total battery voltage drops below 

the set value, an alarm is activated.

Weakest Cell Alarm 

 - Set low-voltage signalling for the cell. If the measured voltage of any cell 

falls below the set value, the alarm is activated.

Difference  Alarm

  - Alarm signalling  for a large voltage  difference  between the strongest and  the

weakest cells. If the measured voltage exceeds the set value, the alarm is activated.

4.5.

MULi6s Module MENU MODE: SERVICE - 

Press the D (down arrow) key to enter the 

firmware version display and restore the default sensor settings.

Factory Defaults

 - Press R and L (right and left) simultaneously to upload the MULi6s Module 

sensor default setting.

MULi6s  Modul  v.  Xx.xx     ID   xxxxx  :  xxxxx

  –  Product   name   with   firmware   version  and  serial

number (ID).

8

Summary of Contents for MULi6s EX

Page 1: ...INSTRUCTIONS FOR USING SENSOR MULI6S MODULE Producer JETI model s r o 14 12 2017...

Page 2: ...6s Module SENSOR CONNECTION OPTION 6 3 1 Jetibox 6 3 2 Receiver 6 4 MENU JETIBOX 7 4 1 Actual values 7 4 2 Min Max 8 4 3 Settings 8 4 4 Alarms 8 4 5 Service 8 5 CONFIGURATION USING A DC DS TRANSMITTER...

Page 3: ...sor connection Muli6s Module Notice Try to follow the following connection procedure 1 Connect the MULi6s Module sensor to the Li XX battery connector Make sure the connector polarity is correct 2 Con...

Page 4: ...go out after a while Then the LED always lights for 0 3s and displays the state of the weakest cell to save the potential of the first two cells To put the module back into sleep mode just unplug the...

Page 5: ...Instructions manual MULi6s Module Notice Only use wires that are part of the sensor for serial connection of modules 5...

Page 6: ...s because the siren is part of a transmitter module that is not connected in this case Alarms are only displayed on the LCD 2 Connect the 3 wire MULi6s Module sensor cable with the JR connector to the...

Page 7: ...ead data When connected to the MULi6s Module a startup screen appears which contains the sensor identification and the number of connected battery cells on the first row of the sensors of all connecte...

Page 8: ...minimum and maximum will be reset when the sensor is switched on for the first time 4 4 MULi6s Module MENU ALARMS Press the D Down Arrow button to enter the individual alarm settings If a set paramet...

Page 9: ...will go to the configuration menu Reset to factory defaults to retrieve the default MULi6s Module setting 5 1 Telemetry Total voltage shows the current total battery voltage and the number of all con...

Page 10: ...kest and strongest cells throughout the flight In addition to the voltage which of the two cells this difference affects the first number corresponds to the strongest cell MIN MAX Telemetry of all cel...

Page 11: ...Consumption 70uA Maximum of connected modules 5 Number of batteries connected to one module 1 Maximum number of cells connected to one module 6 Maximum voltage on one module 26 4V 8 Guarantee The prod...

Page 12: ...Instructions manual MULi6s Module MULi6s Module menu displayed on JETIBOX terminal 12...