
computer radio control system
EN
9.4.3 Vario
Located in:
„Menu->Timers/Sensors/Vario”.
There are two types of
acoustic signalling. The first one is controlled directly by the sensor's
alarm. This is mainly useful if a non-EX MVARIO is installed inside the
model. It is possible to assign a switch that enables or disables the
sound. The slider at the bottom shows the actual value of climb/sink
rate.
The second mode of the Vario is dedicated to EX sensors. The
acoustic signalling varies directly depending on the actual
numerical values sent by the sensor. It is also possible to assign a
switch that enables the acoustic signal.
Other parameters displayed in this menu are:
•
EX Parameter. Here you can select your sensor and its
parameter which will act as a source for the Vario system. The Climb
Rate is predefined by default (if the MVARIO EX is detected) but you
are free to choose one of the other sensors and their parameters (for
example: an RPM probe to indicate high revolutions).
•
Dead Zone (negative and positive). This field sets an area
around the centre of the range with no acoustic signal. Values are
relative to the center.
•
Range (minimum, center and maximum). Here you can define
the full range of the sensor which will be indicated by the Vario
system.
The actual value of the sensor and its appropriate Vario output are
indicated at the bottom of the screen.
Centre of range
Negative dead zone
Positive dead zone
Silence
Permanent sound
Beeping...
Minimum
Maximum
9.4.4
Voice Output
This powerful function makes it easier for all modellers who need to
know their actual telemetry values often but they don't want to (or
cannot) look at the display because it may be inconvenient or
dangerous.
1.
Voice output for a timer
The first menu row represents settings for the voice output of a timer.
The actual status of a single timer can be expressed by a synthesized
voice. If you select the desired timer and a switch, every time the
switch is activated the actual time is stated aloud.
If the timer type equals “Laps” type, another menu row equipped
with checkbox appears below. In this row, “Report previous lap”
4.
4.
121
Summary of Contents for DUPLEX DC-24
Page 2: ...computer radio control system EN...
Page 67: ...computer radio control system EN 3 3 65...
Page 166: ...computer radio control system EN 5 5 164...
Page 167: ...computer radio control system EN...
Page 168: ...computer radio control system EN JETI model s r o Lomen 1530 742 58 P bor www jetimodel com...