Page 29/39
The INFO Menu
Info menu displays the following information:
Value
Explanation
Rest Fuel
Remaining fuel in tank. Tank size can be entered using the
LIMITs
menu. Value is reset every time the ECU is switched on (or can be
reset manually by pressing the
Change Value/Item
button on the
GSU).
Fuel Flow ml/min
Actual fuel consumption in ml/min.
BattCnd
Ubattery
The condition of the battery is indicated in the upper line:
1.
--OK--
2.
!WEAK!
3. --EMPTY--
1. If the battery voltage is 1.1V/Cell or higher “
—OK--
“ will be
displayed.
2. If the battery voltage drops under 1.1V/Cell, the display will read
“
!WEAK!”
. Red
Standby/Manual
and green
OK
LED’s will
blink simultaneously (at a rate of twice per second). Starting the
turbine is not possible, until the battery is recharged. If the
turbine is already running and the battery warning function is
enabled, the warning function will be activated.
3. If the battery voltage drops under 1.0V/Cell “—
EMPTY--
”
is
displayed. Starting the turbine is not possible until the battery is
recharged. If the turbine is running, it will be immediately shut
off, to avoid a malfunction of the ECU.
Current voltage of the battery. Displayed on bottom line.
Last Run Time
Last turbine run time.
Last Fuel Count
Quantity of fuel consumed, during the last turbine run.
Last-Off PmpVolt
Volts applied to the pump when it was switched off.
Last Off RPM
RPM of the turbine, when it was switched off.
Last Off TEMP
Temperature of the turbine, when it was switched off.
Last Off Cond
Last stored Off condition.