Explanation for Turbine Shut Down
In the run menu, state selection, are the following explanations for the last shut down
condition of the turbine.
Value
Explanation
Manual
AUX switched to
Off
position or throttle stick and throttle trim moved to
the minimum position.
OverTemp
Turbine running over temperature.
IgnTimOut
Turbine did not ignite within programmed time interval.
AccTimOut
Turbine achieved ignition, but did not accelerate within programmed time
interval.
Acc. Slow
Turbine achieved ignition, but acceleration was less than the
programmed value, during startup.
Over-RPM
Turbine exceeded the maximum RPM, by 5%.
Low-RPM
Turbine running under the minimum RPM, by 10%. Usually triggered by
a flame out.
BattryLow
Battery pack dead. Cell voltage is < 1.0V.
HiTempOff
EGT exceeded the maximum range (~950 °C).
Auto-Off
Turbine shut down via the
AutoOff
sequence, using the AUX channel.
LowTemp
EGT dropped below the minimum value. A dislodged EGT sensor can
trigger this shut down.
GlowPlug!
Defective glow plug.