19
15.0
Troubleshooting the JPM-13CS
15.1
Mechanical and electrical problems
Trouble Probable
Cause
Remedy
Table difficult to
adjust.
Lack of lubrication on corner posts and
screws.
Lubricate corner posts and screws.
Chain is jumping.
Inadequate tension.
Adjust chain tension.
Sprockets misaligned.
Align sprockets.
Sprockets are worn.
Replace sprockets.
Machine will not
start/restart or
repeatedly trips circuit
breaker or blows
fuses.
No incoming power.
Verify power connections to planer.
Building circuit breaker trips or fuse
blows.
Verify that planer is on a circuit of
correct size. Check amp setting on
motor. If circuit size is correct, there is
probably a loose electrical lead.
Loose electrical connections.
Go through all the electrical
connections on the planer including
motor connections, verifying the
tightness of each. Look for any signs of
electrical arcing which is a sure
indicator of loose connections or circuit
overload.
Motor failure.
If electric motor is suspect, you have
two options: Have a qualified electrician
test the motor for function or remove
the motor and take it to a qualified
electric motor repair shop and have it
tested.
Miswiring of the unit.
Check to confirm all electrical
connections are correct and properly
tight. Make any needed corrections.
On/off switch failure.
If the on/off switch is suspect, you have
two options: Have a qualified electrician
test the switch for function, or purchase
a new on/off switch and establish if that
was the problem on changeout.
Summary of Contents for JPM-13CS
Page 22: ...22 16 1 1 Table and Base Assembly Exploded View...
Page 26: ...26 16 3 1 Gearbox Assembly Parts List...
Page 28: ...28 16 4 1 Stand and Motor Assembly Parts List...
Page 30: ...30 17 0 Electrical Connections...
Page 31: ...31...
Page 32: ...32 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...