10
2E – MAINTENANCE
1-
Descale the boiler, the internal surface of
the tank and the appliance water piping
once or twice a year.
2-
Descale the rinse and wash jets every
month using vinegar or a descaling agent.
3-
The internal hose of the rinse aid and
detergent peristaltic dispenser should
undergo periodic maintenance (once or
twice a year).
4-
Clean solenoid valve filter by removing it
from the inside of the valve and
unplugging the water inlet tube.
2F – UNINSTALL (Long period of
inactivity)
Machine can be taken out of operation
only by trained technicians authorized
for the purposes, who will provide the
following:
1-
Shut water line off (water valve) and
electric supply (main breaker).
2-
Completely drain the tank.
3-
Remove and carefully clean the filters.
4-
Completely
drain
the
incorporated
dispenser hoses, removing them from the
containers.
5-
Drain the detergent and rinse aid nozzles
with fresh water first and after with water
and glycerine (50% - 50%) taking care that
nozzles remain clean and lubrified inside.
6-
Drain the booster completely by removing
the screw located under the machine.
7-
Spread a thin film of vaseline oil over all
the stainless steel surfaces.
INSTALLER REMARKS
INSTALLATION DATE:__________________________
INSTALLATION PLACE:_________________________
INSTALLER NAME:__________________________
MACHINE SERIAL NUMBER:___________________
SIGNATURE:____________________________________