6. Installation example
Fig.1
MAGDOS DE/DX 40 and DE/DX 100 can only be
mounted parallel to the wall.
Fig. 3
Fig. 2
1 MAGDOS
MB 1 02 00
2 Suction line with integrated
level control
MB 1 22 01
3 Hand mixer
MB 1 36 02
4 Chemical tank
MB 1 20 01
5 Leakage probe for monitoring
the diaphragm
MB 1 31 01
6 Relief/safety valve
MB 1 25 01
7 Shutoff valve for isolating the
pump from the plant
MB 1 24 01
8 Back pressure valve for max.
metering accuracy
MB 1 25 01
9 Injection nozzle with non-return
valve
MB 1 23 01
10 Venting as separate part or
MB 1 33 02
integrated in the metering head
MB 1 33 03
11 Water meter with contact unit
MB 1 37 01
12 Pulsation dampener for reducing
pressure peaks and smoothing
the flow
MB 1 27 01
13 Separation chamber
is recommended if the media
could damage the pump in the
case of a diaphragm failure
MB 1 28 01
ATTENTION!
Leakage must be discharged
into a collection funnel using
a short inclining drain pipe
(and can then be returned to
the chemical tank).
The outlet of the drain pipe
must be visible in order to
actually see the leakage.
14 Priming aid
This equipment allows easy
startup of small pumps in particular.
The entrained gas serves as a
pulsation dampener.
MB 1 33 01
15 Water meter spacer
MB 1 37 01
ATTENTION!
The spacer is required to
avoid that the drive solenoid
affects the water meter
contact.
16 Wall bracket
MB 1 32 00
17 Tall or short adapter for tank
mounting