10 |
Operation & Maintenance Instructions
FLOWCON | Technical data
4. Technical data
4.1 Flow Sensor FLOWCON
Housing material
PVC and PMMA
Sealing material
FPM or EPDM
Connections
Inlet:
Union nut G 5/8 or G 3/4
Outlet:
G 5/8 or G 3/4 spigot
Dosing range
Solenoid-driven dosing pump
0.05...1 l/h
(Not applicable for MAGDOS LT 17.)
Motor-driven dosing pump
0.5...50 l/h
Max. system pressure
10 bar
Max. viscosity at stroke frequency 100/min
0 mPa∙s (0 cps)
Max. viscosity at stroke frequency 150/min
10 mPa∙s (10 cps)
Max. temperature of process fluid
35 °C (95 °F)
Switching capacity of reed contact
48 VAC/DC, 0.5 A, max. 1 VA
4.2 Electronic Evaluation Unit FLOWCON
Mounting
Wall mount IP65 or Panel mount
Electrical data
30 VAC, 1 Ph, 50/60 Hz, 5VA
115 VAC, 1 Ph, 50/60 Hz, 5VA
Alarm relay
switching capacity
30 VAC or 110VAC, 4 A
1-pole switch, normally open at alarm
Display
1 red LED (Start)
blinks short on triggering of a stroke. Blinks long on a faulty stroke.
1 green LED (Flow)
blinks on every stroke that is verified by the stroke sensor.
1 green LED (0)
is ON as long as there is no faulty stroke.
7 green LED‘s (Error)
indicate faulty strokes by turning red.
1 red LED (Alarm)
lights when the number of allowable faulty strokes is exceeded (alarm output relay switches).