Setting the Functions Continued 

 

7.  Setting  the  Buzzer.  (see  screen  #8  on  page  7) 

Get  to  screen  #8  with  [d03] 

showing with the 3 flashing on the display by following the instructions on pages 6&7. 
The  buzzer  can  be  set  as  an  indicator,  an  alarm  or  to  enable  or  disable  various 
functions. The chart below shows what each digit controls; 

 

 

2

nd

 digit (tens place) 

 

0=Buzzers Enabled / Reverse Count Enabled 

 

1=Buzzers Enabled / Reverse Count Disabled 

 

2=Buzzers Disabled / Reverse Count Enabled 

 

3=Buzzers Disabled / Reverse Count Disabled 

 

 

1

st

 digit (ones place) 

 

2=Clutch Signal Buzzer Disabled 

 

3=Clutch Signal Buzzer Enabled 

 

To set the Buzzers, press and release 

F3

 to increase the ones digit between 2 and 3. 

Press and release 

F2

 to select the tens digit. Press and release 

F3

 to increase the tens 

digit between 0 and 3. Press and hold 

F1

 for more than 2 seconds to save and exit.  

 

8. Setting the Min/Max Alarm Buzzer. (see screen #9 on page 7) 

Get to screen #9 

with  [U  3]  showing  with  the  3  flashing  on  the  display  by  following  the  instructions  on 
pages  6&7.  The  Min/Max  Alarm  Buzzer  can  be  set  as  an  alarm  to  alert  when  the 
Trigger  is  released  or  the  clutch  activates  and  the  motor  revolutions  are  below  the 
Minimum number set or above the Maximum number set. The chart below shows what 
each digit controls; 

 

 

1

st

 digit (ones place) 

 

0=Neither the Minimum or the Maximum Alarms will sound 

 

1=Only the Minimum Alarm will sound 

 

2=Only the Maximum Alarm will sound 

 

3=Both the Minimum and the Maximum Alarms will sound 

 

To set the Buzzers, press and release 

F3

 to increase the ones digit between 0 and 3.  

Press and hold 

F1

 for more than 2 seconds to save and exit.  

 

9.  Viewing  the  Cycle  Totals.  (see  screen  #10  on  page  7) 

Get  to  screen  #10  with 

[L00} showing on the display. These numbers indicate the total number of cycles where 
the  clutch  activates  whether  the  Count  is  On  or  OFF.  Running  the  tool  and  releasing 
the trigger before the clutch activates will not count as a cycle. These numbers can be 
used  to  determine  when  to  perform  maintenance  or  to  rotate  the  tool  out  of  service. 
The  picture  below  shows  how  to  read  the  numbers. 

Note!  These  numbers  can’t  be 

adjusted. Nothing will appear until after 99,999 Cycles and the maximum will be 9,999,999 Cycles. 

 
 

 

Summary of Contents for ASG HIOS BLG BC2

Page 1: ...Page 1 HIOS BLG BC2 Programming Instructions Dec 2015 ...

Page 2: ...nctions 7 10 Enable or Disable Error Proofing 7 Fastener Count 7 Setting the Minimum Revolutions 8 Setting the Maximum Revolutions 8 Setting the Work Reset Timer 8 Setting the Reverse Count timer 8 Setting the Buzzer 9 Setting the Min Max Alarm Buzzer 9 Viewing the Cycle Totals 9 Adjust the Re Hit Timer 10 Additional Common functions 10 Reset the Count 10 Exiting the User Interface Saving Changes ...

Page 3: ...perly driven fasteners BC2 tools also feature an optional I O capability which when combined with a PLC can provide full process control User Interface Display and Button Functions The BC2 interface will show numbers letters or symbols depending what mode the system is in It also contains red FAIL LED a green PASS LED and 3 programing buttons F1 F2 F3 complete the BC2 tool interface 1 Screw Count ...

Page 4: ...ns to change the values in the Set Up Function Some values are limited depending on the function being set Press and hold the F2 button until r 0 is displayed and the Pass Fail lights blink This will put the tool in the joint learning mode 5 Pass LED When the fastener is driven properly the Green LED is lit 6 Fail LED When the fastener is not driven properly the Red LED is lit The LED will remain ...

Page 5: ...ged by the selected Example Say the reference values for an acceptable fastener are Min 90 and Max 120 and the range selected is 0 Any fastener driven where the motor turns between 91 and 119 revolutions and the clutch shuts off will result in a Pass or Green LED Fewer than 90 or more than 120 revolutions will result in a Fail or Red LED If the motor is run for 90 revolutions or more and the trigg...

Page 6: ...er or an improper length fastener Navigating the User Interface The following shows the different displays as seen in the order they appear as you scroll through the different functions by pressing and releasing the F1 button The numbers shown in the display drawings below are the factory default settings and will change to reflect the values you choose for your application Instructions on how to ...

Page 7: ...ing press and hold F1 for more than 2 seconds The letter P will show on the display until the button is released When the button is released either the word On or OFF will show on the display Press and release F3 to toggle between On and OFF Press and hold F1 for more than 2 seconds to save and exit When OFF is selected the tool will operate like a regular driver 2 Fastener count see screen 3 on p...

Page 8: ...lutions on the display while the fastener is being driven then the total number of actual motor revolutions will stay visible for a moment before the display defaults to the remaining fastener count 5 Setting the Work Reset Timer see screen 6 on page 6 Get to screen 6 with 1 0 showing with the 0 flashing on the display by following the instructions for navigating on page 6 The Work Reset Timer con...

Page 9: ...nstructions on pages 6 7 The Min Max Alarm Buzzer can be set as an alarm to alert when the Trigger is released or the clutch activates and the motor revolutions are below the Minimum number set or above the Maximum number set The chart below shows what each digit controls 1st digit ones place 0 Neither the Minimum or the Maximum Alarms will sound 1 Only the Minimum Alarm will sound 2 Only the Maxi...

Page 10: ... all fasteners have been installed the count can be reset to the starting number at any time To reset the count press and hold F3 for more than 2 seconds The word HIOS will scroll across the display and the display will reset to the starting count 2 Exiting the User Interface exiting also saves any changes made to the values The User Interface can be exited at any particular point without scrollin...

Page 11: ...en a 0 is seen before the count is reset to the starting count The Work Reset Timer controls how long the green LED stays lit the buzzer beeps and 0 remains on the display before the counter resets to the starting count The Reverse Count Timer sets a time period where removing a fastener will increase the count shown on the display by one After this time period removing a fastener will not affect ...

Page 12: ...o add I O capability data capturing capability and the ability for process control by interfacing with a PLC or other controls 65665 BLG BC2 I O Cable with sample software 65664 BLG IO Pro 1I O Box ESD Properties BLG tool Housings are constructed with Anti Electrostatic Resin The surface resistance is less than 3x1012 Ω RoHs BLG Tools are RoHs Compliant ...

Reviews: