Page | 5
Quick Start Procedure Continued
2.
Start learning the joint by driving 3 or more of the same fastener into the same joint.
Make sure to use the same fasteners, parts and method of pick up to be used in
production. As you drive each fastener you will see the actual number of motor
revolutions displayed.
3.
Press the
F3
button to select an acceptable range for the Pass/Fail criteria.
This will be displayed in the following order; ±0%,±5%,±10%,±15%,±20%.
4.
Press the
F1
button to confirm the reference values for Pass/Fail and the acceptable
range. The display will alternate between showing the Maximum and Minimum
numbers of motor revolutions for the joint learned. Pressing
F3
while these numbers
are flashing allows you to change the ±% for Pass/Fail and will display the new
numbers for the Maximum and Minimum values as changed by the selected %.
Example,
Say the reference values for an acceptable fastener are
Min 90
and
Max 120
and the range selected is 0%. Any fastener driven where the motor turns
between 91 and 119 revolutions, and the clutch shuts off, will result in a Pass, or
Green LED. Fewer than 90 or more than 120 revolutions will result in a Fail, or Red
LED. If the motor is run for 90 revolutions or more and the trigger is released,
with no clutch shut off (ABORT), the result is a Fail or Red LED.
5.
Press and hold the
F2
button until the buzzer sounds twice, the Minimum and
Maximum values and the word HIOS scroll across the display to complete learning
the joint.
6.
Press and hold
the
F1
button to see [P ] on the display, then release to see [ON ]
show on the display. Press the F1 button once to see [
n
05 ] with t
he “5” flashing.
This would indicate that the count is set to 5 fasteners.
7.
To change the count, press the
F3
button. Each press of the button will increase the
flashing number by one count, up to 9, after 9 the count will start over at 0.