Page | 10 

Setting the Functions Continued 

 

10.  Adjust  Re-Hit  Timer.  (see  screen  #11  on  page 7) 

Get to screen #11 with [≡0.5] 

showing with the 5 flashing on the display by following the instructions on pages 6&7. 
The Re-Hit Timer sets a time period between the clutch shut off and a second or third 
trigger-pull-clutch-shut-off  sequence  before  an  Error  /  Fail  is  registered.  The  Re-Hit 
timer  can  be  set  between  0.0  and  9.9  seconds.  To  set  the  Re-Hit  Timer,  press  and 
release 

F3

 to increase the ones digit between 0 and 9. Press and release 

F2

 to select 

the tens digit. Press and release 

F3

 to increase the tens digit between 0 and 9. Press 

and  hold 

F1

 for  more than 2  seconds  to  save  and exit. 

Note!  the  Re-Hit  Timer  functions 

only when the green Pass LED is lit upon a fastener rundown. 

 

Additional / Common Functions 

 

1. Reset the Count. 

If it becomes necessary to terminate the assembly process before 

all fasteners have been installed, the count can be reset to the starting number at any 
time. To reset the count, press and hold 

F3

 for more than 2 seconds. The word 

HIOS 

will scroll across the display and the display will reset to the starting count. 

   

 

 
 

 

2. Exiting the User Interface. (exiting also saves any changes made to the values) 

The  User  Interface  can  be  exited  at  any  particular  point  without  scrolling  through  the 
remaining screens. 

Example;

 You are at the Count screen and you confirmed that the 

count  is  set  at  5.  To exit  (and  save  any  changes)  press  and  hold 

F1

  for more  than  2 

seconds.  The  next  screen  will  appear  briefly,  the  buzzer  will  beep  twice  (if  enabled) 
and the word 

HIOS

 will scroll across the display. The current count will then show and 

the tool is ready to operate. 

  

 
 
 

 

General Information 

 

Fastener Count. 

The fastener count number seen on the display always registers the 

number of fasteners remaining to complete the assembly.

  

 
Counter  On/OFF. 

Remember  that  when  the  counter  is  turned  off  the  driver  operates 

like a normal driver with no error proofing or counting functions. 
 

Summary of Contents for ASG HIOS BLG BC2

Page 1: ...Page 1 HIOS BLG BC2 Programming Instructions Dec 2015 ...

Page 2: ...nctions 7 10 Enable or Disable Error Proofing 7 Fastener Count 7 Setting the Minimum Revolutions 8 Setting the Maximum Revolutions 8 Setting the Work Reset Timer 8 Setting the Reverse Count timer 8 Setting the Buzzer 9 Setting the Min Max Alarm Buzzer 9 Viewing the Cycle Totals 9 Adjust the Re Hit Timer 10 Additional Common functions 10 Reset the Count 10 Exiting the User Interface Saving Changes ...

Page 3: ...perly driven fasteners BC2 tools also feature an optional I O capability which when combined with a PLC can provide full process control User Interface Display and Button Functions The BC2 interface will show numbers letters or symbols depending what mode the system is in It also contains red FAIL LED a green PASS LED and 3 programing buttons F1 F2 F3 complete the BC2 tool interface 1 Screw Count ...

Page 4: ...ns to change the values in the Set Up Function Some values are limited depending on the function being set Press and hold the F2 button until r 0 is displayed and the Pass Fail lights blink This will put the tool in the joint learning mode 5 Pass LED When the fastener is driven properly the Green LED is lit 6 Fail LED When the fastener is not driven properly the Red LED is lit The LED will remain ...

Page 5: ...ged by the selected Example Say the reference values for an acceptable fastener are Min 90 and Max 120 and the range selected is 0 Any fastener driven where the motor turns between 91 and 119 revolutions and the clutch shuts off will result in a Pass or Green LED Fewer than 90 or more than 120 revolutions will result in a Fail or Red LED If the motor is run for 90 revolutions or more and the trigg...

Page 6: ...er or an improper length fastener Navigating the User Interface The following shows the different displays as seen in the order they appear as you scroll through the different functions by pressing and releasing the F1 button The numbers shown in the display drawings below are the factory default settings and will change to reflect the values you choose for your application Instructions on how to ...

Page 7: ...ing press and hold F1 for more than 2 seconds The letter P will show on the display until the button is released When the button is released either the word On or OFF will show on the display Press and release F3 to toggle between On and OFF Press and hold F1 for more than 2 seconds to save and exit When OFF is selected the tool will operate like a regular driver 2 Fastener count see screen 3 on p...

Page 8: ...lutions on the display while the fastener is being driven then the total number of actual motor revolutions will stay visible for a moment before the display defaults to the remaining fastener count 5 Setting the Work Reset Timer see screen 6 on page 6 Get to screen 6 with 1 0 showing with the 0 flashing on the display by following the instructions for navigating on page 6 The Work Reset Timer con...

Page 9: ...nstructions on pages 6 7 The Min Max Alarm Buzzer can be set as an alarm to alert when the Trigger is released or the clutch activates and the motor revolutions are below the Minimum number set or above the Maximum number set The chart below shows what each digit controls 1st digit ones place 0 Neither the Minimum or the Maximum Alarms will sound 1 Only the Minimum Alarm will sound 2 Only the Maxi...

Page 10: ... all fasteners have been installed the count can be reset to the starting number at any time To reset the count press and hold F3 for more than 2 seconds The word HIOS will scroll across the display and the display will reset to the starting count 2 Exiting the User Interface exiting also saves any changes made to the values The User Interface can be exited at any particular point without scrollin...

Page 11: ...en a 0 is seen before the count is reset to the starting count The Work Reset Timer controls how long the green LED stays lit the buzzer beeps and 0 remains on the display before the counter resets to the starting count The Reverse Count Timer sets a time period where removing a fastener will increase the count shown on the display by one After this time period removing a fastener will not affect ...

Page 12: ...o add I O capability data capturing capability and the ability for process control by interfacing with a PLC or other controls 65665 BLG BC2 I O Cable with sample software 65664 BLG IO Pro 1I O Box ESD Properties BLG tool Housings are constructed with Anti Electrostatic Resin The surface resistance is less than 3x1012 Ω RoHs BLG Tools are RoHs Compliant ...

Reviews: