Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
14
16022880 Rev. 0
©2004 Maytag Services
Illustration Component
Test
Procedure
Results
Oven light socket
Test continuity of receptacle terminals.
Measure voltage at oven light.
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light
check wiring.
Light switch
Measure continuity of switch positions:
Closed ..............................................
Open .................................................
Continuity
Infinite
Autolatch assembly
Disconnect wires and test for
continuity per wiring diagram.
See wiring diagram for schematic layout.
Convection motor
Verify supply voltage ........................
Measure continuity at the following
points:
Terminal to terminal..........................
Terminal to ground ...........................
120 VAC
Continuity
Infinite
Thermostat
Verify supply voltage ...........................
Measure resistance at the following:
Terminal 9 to terminal 6 ...................
120 VAC
Continuity with thermostat on.
No continuity with thermostat off.
Bake element
Measure voltage at bake element...........
Disconnect wire leads to element and
measure resistance of terminals:
4000 Watts .............................................
5000 Watts .............................................
240 VAC, see wiring diagram for terminal
identification. If no voltage is present at
bake element, check wiring.
Approximately 14.4
Ω
, if not replace.
Approximately 11.5
Ω
, if not replace.
Broil element
(8 pass)
Measure voltage at broil element............
Disconnect wire leads to element and
measure resistance of terminals:
4000 Watts .............................................
240 VAC, see wiring diagram for terminal
identification. If no voltage is present at
broil element, check wiring.
Approximately 14.4
Ω
, if not replace.