Jenn-Air JXI8936DS Installation Instructions And Use & Care Manual Download Page 13

13

Complete Installation

Reinstall Motor:

1. Place the motor into the blower module housing positioning it 

with the large keyholes in motor mounting plate towards the 
back of the canopy. 

2. Grasping the motor plate, push the motor up into the blower 

module housing. Locate the large keyholes over the motor 
mounting nuts, push up against the module top cover and 
pull the motor forward to lock into the small keyholes slots. 

3. Use the special ½" (13 mm) tool and tighten the (4) nuts to 

secure the motor.

4. Reconnect 9 pin connector from motor to electrical power.
5. Reconnect power.

Complete Installation:

1. For non-vented (recirculating) installations only, install the 

charcoal filters over the metal mesh filter. See the “Range 
Hood Care” section.

2. Install metal filters. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and light. See 

the “Range Hood Use” section.
If range hood does not operate, check to see whether a 
circuit breaker has tripped or a household fuse has blown. 

NOTE: To get the most efficient use from your new range hood, 
read the “Range Hood Use” section.

RANGE HOOD USE

The range hood is designed to remove smoke, cooking vapors 
and odors from the cooktop area. For best results, start the hood 
before cooking and allow it to operate several minutes after the 
cooking is complete to clear all smoke and odors from the 
kitchen.
The range hood controls are located on the front of the canopy.

Control Panel

Controls and Features

NOTES:

To activate the controls, press and release the desired button.

The control feature button will be lit when a control feature is 
turned On.

Sleep Mode

The range hood automatically enters Sleep Mode when not in 
use. After 10 minutes of no range hood activity, all of the control 
button lights will turn Off. To deactivate Sleep Mode, press any 
button.

Auto Sense

Auto Sense allows the range hood fan to turn on automatically 
when it senses heat higher than its allowable temperature limit. 
When Auto Sense is On, the fan speed will increase or decrease 
based on the temperature Auto Sense is measuring.
Auto Sense can be manually increased by pressing a higher fan 
speed. The fan will run at the selected speed for 10 minutes 
before returning to the speed selected for Auto Sense.
If Auto Sense is On, the Auto button light will turn Off and go into 
Sleep Mode when the vent hood is not in use. If the vent hood is 
turned On by the consumer or by Auto Sense, the Auto button 
light will turn On. 
To set Auto Sense:

Press AUTO.

To Select Auto Sense Cooktop Type:

NOTE: The range hood is factory-set for the gas cooktop 
mode.

Press and hold AUTO for 5 seconds to switch between the 
gas cooktop and electric cooktop modes.

The Auto button light will flash 5 times when the range hood 
is changed to the electric cooktop mode. Auto Sense is now 
set to work with electric cooktops and ranges.

The Auto button light will flash 3 times when the range hood 
is changed to the gas cooktop mode. Auto Sense is now set 
to work with gas cooktops and ranges.

Changing the cooktop type will change the temperature limit 
for Auto Sense to turn On. When the range hood senses a 
high enough temperature, the fan will start automatically. 
When the temperature drops below the set temperature limit, 
the fan will stop automatically. The Auto button light will turn 
Off after the range hood enters Sleep Mode, but Auto Sense 
is still active.

A. Louver holes (non-vented 

[recirculating] installations only)

B. Chimney covers

C. Lamps

D. Filter door glass

E. Canopy glass

F. Canopy

G. Control panel

A

C

D

E

F

G

B

Auto

Low

Med

Hi

Boost Filter Light

Summary of Contents for JXI8936DS

Page 1: ...nair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou...

Page 2: ...ERVICE 17 In the U S A 17 Accessories 17 In Canada 17 WARRANTY 18 TABLE DES MATI RES S CURIT DE LA HOTTE DE CUISINI RE 19 EXIGENCES D INSTALLATION 21 Outils et pi ces 21 Exigences d emplacement 21 Exi...

Page 3: ...is manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety mes...

Page 4: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Page 5: ...model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows...

Page 6: ...seal all joints in the vent system Use caulking to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations An additional back draft damper...

Page 7: ...ned from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused el...

Page 8: ...ing to the large openings in the keyhole slots 5 Remove the motor from the range hood Range Hood Mounting Screws Installation 1 Determine and mark the centerline on the ceiling where the range hood wi...

Page 9: ...g Crosshatch is the open area available for wiring access in the ceiling within the upper chimney area 5 Run the home power supply cable according to the National Electrical Code or CSA Standards and...

Page 10: ...upper chimney cover and into the mounted threaded fasteners F of the range hood canopy 7 Adjust the range hood to the desired height Level the range hood and tighten the screws using a T20 Torx bit Se...

Page 11: ...t damage the wiring 4 Using a T20 Torx driver remove the 2 screws inside the electrical box holding the module plate and the 6 other screws around the perimeter of the module plate A Lower chimney cov...

Page 12: ...onnector 12 Tighten strain relief to secure the home power supply cable 13 Reassemble the electrical connection box cover on the bottom of the module plate assembly 14 Reassemble the module plate asse...

Page 13: ...r 10 minutes of no range hood activity all of the control button lights will turn Off To deactivate Sleep Mode press any button Auto Sense Auto Sense allows the range hood fan to turn on automatically...

Page 14: ...eplace or clean the filter Light Press LIGHT to turn the range hood lights On and Off RANGE HOOD CARE Cleaning IMPORTANT Clean the hood and grease filters frequently according to the following instruc...

Page 15: ...e dishwasher using normal detergent and choosing the highest temperature setting To reactivate the filter the filter should be dried in an oven for 10 minutes with a maximum temperature of 210 F 100 C...

Page 16: ...Motor Speed Resistance 18 40 Ohm 420 W Blue Gray 60 Hz Blue White Component Layout Description Num E M I Filter User Interface Main Board Light Driver Capacitor LED Lamp 6 5 4 3 2 1 L N C 1 3 2 4 Tem...

Page 17: ...on vented installations only Order Part Number W10272069 Chimney Kit Recirculation for 7 9 2 36 m to 10 4 3 15 m ceilings for non vented installations only Order Part Number W10646865 Chimney Extensio...

Page 18: ...light bulbs batteries air or water filters preservation solutions etc 5 Conversion of products from natural gas or L P gas 6 Damage from accident misuse abuse fire floods acts of God or use with prod...

Page 19: ...re appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous sign...

Page 20: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Page 21: ...responsabilit de respecter les distances de s paration sp cifi es sur la plaque signal tique de l appareil La plaque signal tique de l appareil est situ e derri re le filtre de gauche sur la paroi ar...

Page 22: ...t Un conduit en m tal rigide est recommand Ne pas utiliser de conduit de plastique ou de m tal tr s mince Le syst me d vacuation doit comporter un clapet Si la bouche de d charge murale ou par le toit...

Page 23: ...clage de la hotte dot e d un filtre charbon actif et du d flecteur Les fum es et vapeurs sont recycl es travers les persiennes du cache conduit sup rieur Pour commander voir Accessoires dans la sectio...

Page 24: ...min des surfaces de cuisson au gaz et un maximum sugg r de 36 91 4 cm au dessus de la surface de cuisson 1 D connecter la source de courant lectrique 2 D terminer la m thode d vacuation utiliser d ch...

Page 25: ...guichet d couper un trou de 6 16 5 cm de diam tre dans le plafond pour le conduit d vacuation 3 Installer le circuit d vacuation travers le trou du plafond 4 Connecter la partie de conduit flexible s...

Page 26: ...es 2 vis de service de 4 x 13 mm situ es l int rieur du carter du ventilateur de hotte REMARQUE Celles ci sont utilis es pour maintenir la partie inf rieure du cache conduit en hauteur durant l assemb...

Page 27: ...e de montage Tirer vers le bas pour aligner les crous avec les trous du couvercle sup rieur du module Le pousser vers l arri re dans les demi fentes pour le fixer Serrer les 4 crous au moyen de l outi...

Page 28: ...du p rim tre de la platine du module 5 Soulever la platine du sommet du module de la hotte et la poser sur le sommet du module A Couvercle du bo tier de connexion B Vis du couvercle du bo tier de con...

Page 29: ...re avec les crous de fixation du moteur le lever contre le couvercle sup rieur du module et tirer le moteur vers l avant pour le bloquer dans les petites fentes des orifices en trou de serrure 3 Au mo...

Page 30: ...er la fonction Auto Sense d tection automatique Appuyer sur AUTO Pour s lectionner le type de table de cuisson pour la fonction Auto Sense d tection automatique REMARQUE Cette hotte a t configur e l u...

Page 31: ...iltres graisse avant de faire fonctionner la hotte Surfaces externes Afin d viter d endommager la surface externe ne pas utiliser de tampons en laine d acier ou de tampons r curer savonneux Toujours e...

Page 32: ...r glage de temp rature le plus lev Pour la r activation du filtre s cher le filtre dans un four pendant 10 minutes une temp rature maximum de 210 F 100 C D pose des filtres charbon 1 teindre le ventil...

Page 33: ...arte principale Commande d clairage Condensateur Lampe DEL Fusible N N N N 1 N N JA VE JA VE BL BL BL BL 2 JA MAR N 3 MAR MAR BL BU 5 BU R 4 R R GRIS GRIS 3 Neu BU Capteur de temp rature Parasurtenseu...

Page 34: ...Pour de l aide suppl mentaire Si vous avez besoin d aide suppl mentaire vous pouvez crire Jenn Air Appliances en soumettant toute question ou probl me Jenn Air Brand Home Appliances Centre pour l eXp...

Page 35: ...utions de conservation etc 5 Conversion de votre produit du gaz naturel ou du gaz de p trole liqu fi 6 Dommages caus s par accident m susage abus incendie inondations catastrophe naturelle ou l utilis...

Page 36: ...W10640312A 2014 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 4 14 Printed in Germany Imprim en Allemagne...

Reviews: