5
30
²²²²
WALL OVEN UNDER COUNTER
1
1-1/4
²
Dia. Conduit Access Hole*
2
5/8
²
Plywood Floor (Must Support 200 lbs.)
See next page for Support Platform Construction
DIMENSIONS
inches
cm
A
25
63.50
B
24 MIN
60.96
C
29-1/16 + 1/16
73.82
D
24 MIN
60.96
E
28-1/2
72.39
I
36
91.44
J
1-1/2
3.81
NOTE:
*
Hole must be cut as close to corner of cabinet
as possible.
**
See dealer for approved cooktops.
INSTALLATION
INSTRUCTIONS
30
²²²²
Under Counter
Wall Oven
403 WEST FOURTH STREET, NORTH
NEWTON, IA 50208
30
²²²²
WALL OVEN
inches
cm
K
3 MAX
7.62 MAX
NOTES
Z
Do not block air exhaust slots along bottom of oven.
Y
Gas or electric cooktops may be installed over ovens.**
See cooktop installation instructions for cutout size.
W
Electrical connection for electric cooktop must in
adjacent accessible location. Cook top and wall oven
must be on separate 120/240 or 120/208 volt
60 Hz AC circuits.
SIDE AND/OR TOP FILLERS
MAY BE NECESSARY IF UNIT
IS POSITIONED BETWEEN
EXISTING CABINETS. BE
SURE THEY ARE ATTACHED
SECURELY, SINCE THEY WILL
ANCHOR THE OVEN IN THE
CABINET.