INSTALLATION INSTRUCTIONS

Prepare Location

It is recommended that the vent system be installed before 
hood is installed.

Before making cutouts, make sure there is proper clearance 
within the ceiling or wall for exhaust vent.

Check your ceiling height and the hood height maximum 
before you select your hood.

1. Disconnect power.
2. Determine which venting method to use: roof, wall, or non-

vented.

3. Select a flat surface for assembling the range hood. Place 

covering over that surface.

4. Using 2 or more people, lift range hood onto covered surface.

Range Hood Mounting Screws Installation

5. Determine and mark the centerline on the wall where the 

canopy hood will be installed.

6. Select a mounting height between a minimum of 

18" (45.7 cm) for an electric cooking surface or a minimum of 
22" (55.9 cm) for a gas cooking surface, and a suggested 
maximum of 24" (61.0 cm) above the range to the bottom of 
the hood. Mark a reference line on the wall.

7. Tape template in place, aligning the template centerline and 

bottom of template with hood bottom line and with the 
centerline marked on the wall.

8. Mark centers of the fastener locations through the template 

to the wall. For rear venting through the wall, mark the 
opening for the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent. 
IMPORTANT: All screws must be installed into wood. If there 
is no wood to screw into, additional wall framing supports 
may be required.

Remove the template.

9. Drill 

³⁄₁₆

" (4.8 mm) pilot holes at all locations where screws are 

being installed into wood.

10. Install the 2 - 5 x 45 mm mounting screws. Leave a 

¹⁄₄

" (6.4 mm) gap between the wall and the back of the 

screw head to slide range hood into place.

Vent Cover Bracket Installation (for vent cover 
installation only)

1. Attach vent cover bracket to wall flush to the ceiling using 

2 - 5 x 45 mm screws.

Complete Preparation

1. Determine and make all necessary cuts in the wall for the vent 

system. Install the vent system before installing the hood. See 
“Venting Requirements” section.

2. Determine the required height for the home power supply 

cable and drill a 1¼" (3.2 cm) hole at this location.

3. Run the home power supply cable according to the National 

Electrical Code or CSA Standards and local codes and 
ordinances. There must be enough ½" conduit and wires from 
the fused disconnect (or circuit breaker) box to make the 
connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.

4. Use caulk to seal all openings.

A. Centerline
B. Mounting height reference

WARNING

Excessive Weight Hazard

Use two or more people to move and install 
range hood.

Failure to do so can result in back or other injury.

A

B

A. Ceiling
B. Wall

C. Centerline

¹⁄₄

"

(6.4 mm)

A

C

B

Summary of Contents for 32inch (81.3 CM) WALL-MOUNTPERIMETRIC RANGE HOOD

Page 1: ...site at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance i...

Page 2: ...l installation 27 UTILISATION DE LA HOTTE 28 Commandes de la hotte 28 ENTRETIEN DE LA HOTTE 29 Nettoyage 29 SCH MA DE C BLAGE 30 ASSISTANCE OU SERVICE 31 Au Canada 31 Accessoires 31 GARANTIE 31 RANGE...

Page 3: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Page 4: ...bserve all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial r...

Page 5: ...per If the roof or wall cap has a damper do not use the damper supplied with the range hood Use caulking to seal exterior wall or roof opening around the cap The size of the vent should be uniform Col...

Page 6: ...d OH 44131 5575 A 120 Volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail...

Page 7: ...cm rectangular vent IMPORTANT All screws must be installed into wood If there is no wood to screw into additional wall framing supports may be required Remove the template 9 Drill 4 8 mm pilot holes a...

Page 8: ...g 5 Remove the 4 mounting screws holding the 8 20 3 cm diameter transition damper to the canopy top Set the damper and mounting screws aside 6 Remove the 4 screws holding the blower motor to the canop...

Page 9: ...opy using 3 of the the screws removed from the 8 20 3 cm diameter transition damper Tighten screws Install Range Hood NOTE For rear venting installations the 3 x 10 8 3 x 25 4 cm damper must be assemb...

Page 10: ...bottom of the hood exhaust outlet 3 Cut the duct to the measured size X 4 Remove the air deflector 5 Slide the duct onto the bottom of the air deflector 6 Place the assembled air deflector and duct o...

Page 11: ...lief screw 9 Install terminal box cover 10 Check that all light bulbs are secure in their sockets 11 Reinstall top cover using 5 screws removed previously Tighten screws 12 Reconnect power A Cover scr...

Page 12: ...ood Care section 3 Check the operation of the range hood blower and light See the Range Hood Use section NOTE To get the most efficient use from your new range hood read the Range Hood Use section RAN...

Page 13: ...Reinstall the filter by making sure the spring release handles are toward the front Insert aluminum filter into upper track 5 Push in spring release handle 6 Push up on metal filter and release handl...

Page 14: ...rd Y BR W R BK BU GY Y G Y Y Y Y Y Y Y Y TRANSFORMER Capacitor High Speed Switch Operation FUNCTION Off Lamps Low Speed POSITION Brown Yellow L LA Med Speed Brown White L 1 Brown Red L 2 Brown Black L...

Page 15: ...mber W10272074 White Parametric Trim Kit Order Part Number W10272066 Oil Bronze Order Part Number W10272067 Black In Canada Call the dealer from whom your appliance was purchased or call Jenn Air at 1...

Page 16: ...R OF IMPLIED WARRANTIES IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLO...

Page 17: ...re appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous sign...

Page 18: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Page 19: ...10 8 3 x 25 4 cm 2 chevilles d ancrage mural de 8 x 40 mm 4 chevilles d ancrage mural de 10 x 50 mm Exigences d emplacement IMPORTANT Observer les dispositions de tous les codes et r glements en vigu...

Page 20: ...m talliques Des conduits m talliques rigides sont recommand s Ne pas utiliser de conduit en plastique ou en feuille m tallique La longueur du circuit d vacuation et le nombre de coudes doit tre r dui...

Page 21: ...n Pour les installations sans d charge l ext rieur recyclage sans cache conduit uniquement Installations sans d charge l ext rieur recyclage S il n est pas possible d vacuer les fum es et vapeurs de c...

Page 22: ...ion et de tous les codes et r glements en vigueur INSTRUCTIONS D INSTALLATION Pr paration de l emplacement Il est recommand d installer le circuit d vacuation avant de proc der l installation de la ho...

Page 23: ...depuis le tableau de distribution avec fusibles ou disjoncteurs pour r aliser facilement le raccordement dans le bo tier de connexion de la hotte REMARQUE Ne pas mettre le syst me sous tension avant...

Page 24: ...r vers le bas pour l immobiliser et aligner les trous destin s aux vis de montage Installer les vis de montage et les serrer 10 Rebrancher la fiche du ventilateur 11 Remonter la vitre centrale sur l a...

Page 25: ...l ext rieur uniquement 1 Installer le circuit d vacuation sur le raccord de transition 2 Serrer le raccord avec des brides de serrage 3 V rifier que les clapets anti retour fonctionnent correctement P...

Page 26: ...homologation UL ou CSA 4 Acheminer le cordon d alimentation du domicile travers le serre c ble dans le bo tier de connexion A Vis de montage du clapet A A Vis du couvercle B Couvercle sup rieur AVERTI...

Page 27: ...des sections sup rieure et inf rieure du cache conduit pousser la section inf rieure vers le bas sur la hotte et soulever la section sup rieure vers le plafond pour installer l aide des deux vis de 4...

Page 28: ...tilateur Les boutons FAN SPEED vitesse du ventilateur permettent d allumer le ventilateur et d en contr ler la vitesse ainsi que le niveau sonore ce qui permet de le faire fonctionner sans bruit On pe...

Page 29: ...enfoncer la partie centrale inf rieure pour l embo ter Filtres d installation sans d charge l ext rieur recyclage Le filtre charbon n est pas lavable Celui ci devrait durer pendant six mois dans des c...

Page 30: ...JA VE JA JA JA JS JA JA JA JA TRANSFORMER Capacitor Vitesse lev e Fonctionnementducommutateur FONCTION Off arr t Lampes Vitesse basse POSITION Marron Jaune L LA Vitesse moyenne Marron Blanc L 1 Marro...

Page 31: ...ompter de la date d achat lorsque ce gros appareil m nager est install utilis et entretenu conform ment aux instructions jointes au produit ou fournies avec la marque Jenn Air de Whirlpool Corporation...

Page 32: ...plus tendue ou plus compl te que la garantie limit e fournie avec ce gros appareil m nager adressez vous Jenn Air ou votre d taillant pour obtenir les modalit s d achat d une garantie tendue LIMITATI...

Reviews: