background image

9

Guarantees

9

In keeping with our quality policy JELD-WEN offers the 
following guarantees on its products. These guarantees 
are subject to JELD-WEN UK Terms and Conditions of 
Sale. Defects that are caused in whole or in part by 
failure to adhere to JELD-WEN UK recommendations 
relating to storage, handling, installation, decoration, 
glazing and maintenance, are not covered by these

10 year guarantee against manufacturing 
defects

10 year guarantee on insulating glass units

 

Where windows are supplied factory glazed, all 
elements of the glazing system are covered by  
this guarantee

40 year guarantee against rot and fungal 
attack on all softwood timber components

10, 8 or 6 years guarantee on factory finished 
Hi-Build painted, depending on exposure 
conditions and colour

6 year guarantee on factory stained finished 
products depending on exposure conditions

Exceptional wear and tear of hardware through 
extreme use is not covered. JELD-WEN will accept no 
responsibility for products cut down in size after receipt, 
or when utility or structural strength is impaired in 
fittingor application of hardware.

Hinges and other hardware must never be painted, and 
must be kept clean and lightly lubricated at all times. 
Use Vaseline or neutral oil. Keep rivets and moving 
parts lightly lubricated. Lubricate at least once a year, 
in coastal areas and/or places with high pollution, clean 
and lubricate more often.

The fitting instructions where supplied must be followed 
and the assembly, fitting procedures described must be 
strictly adhered to. Copies of product fitting instructions 
are available for download from 

www.jeld-wen.co.uk

All joinery shall be installed correctly in accordance with 
normal trade practices and adequately maintained in 
service. In case of replacement windows, reveals must be 
sterilised before new joinery is fixed.

All undecorated joinery supplied in the white must be 
suitably primed or stained without delay after receipt, 
all joinery supplied primed must receive further coats 
(undercoat and top coat) of paint within three months 
of purchase, and one month if basecoat stained. If 
primed and in particular basecoat stain finishes have 
deteriorated because of prolonged exposure, the surface 
must be properly prepared, and re-primed before 
finishing and a knotting solution should be applied 
over any visible knots. Take care not to paint over any 
form of weatherstrip as this will adversely affect the 
performance. Any surfaces subsequently cut, particularly 
those exposing end grains, must be brush coated with 
preservative and if required for paint finish must also 
be primed before the joinery is fixed in position in 
accordance with British and European Standards. 

Standard insulating glass units must not be used in areas 
of high humidity, e.g. swimming pools or similar. They 
should also not be used within 300mm from a door or 
within 800mm of the floor, for these areas the glass 
must be toughened. Contact JELD-WEN if in doubt for 
your particular installation.

The decorative finish applied to external joinery and 
cladding, must be maintained in service and moisture 
must not be allowed to penetrate into the timber 
throughout its life.

Regular maintenance of the paint or stain finish of the 
frame is essential for the long-term performance of all 
the components of your timber windows. The period 
between maintenance checks will vary depending on the 
type of paint or stain finish and also the local conditions 
for the site. 

External joinery must be cleaned at a maximum of six 
monthly intervals using a mild non-abrasive cleaner 
and soft cloth. Both internal and exterior faces should 
be cleaned. Make regular checks to ensure that any 
drainage holes, channels and spaces are kept clear. Use 
a soft flexible brush or pipe cleaner with care to remove 
obstructions. Finished joinery is guaranteed against 
blistering, cracking, flaking or erosion excluding natural 
resin exudation and movement around knots.

STORMSURE/STORMSURE /REGENCY      

FITTING & FIXING GUIDELINES

10

 

YEARS

MANUFACTURING

10

 

YEARS

HI-BUILD PAINT

HI-BUILD STAIN

6

 

YEARS

ROT & FUNGAL

40

 

YEARS

GLAZING

10

 

YEARS

JWW3203_18708_Stormsure _Fit_instruct_A5.indd   9

JWW3203_18708_Stormsure _Fit_instruct_A5.indd   9

09/02/2021   11:52

09/02/2021   11:52

Summary of Contents for Stormsure

Page 1: ... injury during manual handling and particular precautions are required when working at height The following instructions and recommendations must be followed Failure to do so may affect the guarantee and the long term performance of the window and glazing JWW3203_18708_Stormsure Energy _Fit_instruct_A5 indd 1 JWW3203_18708_Stormsure Energy _Fit_instruct_A5 indd 1 09 02 2021 11 52 09 02 2021 11 52 ...

Page 2: ...04 Installation 05 Hinge Operation 06 Maintenance 08 Performance 08 Guarantees 09 Troubleshooting Guide 11 IMPORTANT Installation of these Windows should be carried out by a minimum of two people Prior to installing the product please ensure you have carefully inspected each package In the unlikely event you discover any damage or defect do not proceed to fit until you have notified JELD WEN 0845 ...

Page 3: ...uld be in no longer than 7 years In more severe locations it is recommended to carry this out more frequently to maintain protection Microporous paint that is either water or solvent oil based can be used Manufacturer s instructions must be followed paying particular attention to temperature at the time of application Cleaning When cleaning the outside or inside of windows fitted with projecting h...

Page 4: ...use and encourage hot humid conditions There should be space for air to circulate around the windows Factory finished and or glazed windows need extra care to avoid damage to the painted surfaces or glass They should be stored vertically to prevent water accumulating on top of the glazing units When being removed from storage windows should be lifted not dragged They should be lifted by the main f...

Page 5: ...evels of air tightness There should be a correctly installed damp proof course around all the openings to prevent moisture moving from the outer construction to the inner construction There should be adequate insulation fitted between the inner and outer construction to reduce heat loss at the window openings The window should be positioned in the opening such that it covers at least 30mm of the i...

Page 6: ...rt the key head into the groove of the locking button and rotate in the direction indicated to unlock 2 Repeat to top and bottom hinge Note If restrictor has been fitted it must be released prior to attempting the easy clean function 3 Safely holding the sash push towards the centre of the opening The sash will slide to its limit on the hinge 4 By closing the sash the hinges return to the fire egr...

Page 7: ...on Gently lift the restrictor arm A to disengage restrictor and push sash open Some top hung sashes will have a restrictor fitted to both sides Side hung operation Gently pull the restrictor arm A towards you and push sash open Hinge Operation cont 6 STORMSURE STORMSURE ENERGY REGENCY FITTING FIXING GUIDELINES JWW3203_18708_Stormsure Energy _Fit_instruct_A5 indd 7 JWW3203_18708_Stormsure Energy _F...

Page 8: ... drainage holes channels and spaces are kept clear Use a soft flexible brush or pipe cleaner with care to remove obstructions Leaded lights Like any natural lead product exposed to the environment lead profile will undergo certain atmospheric transformation This is perfectly natural and it will eventually settle down to take on the traditional weathered lead appearance so admired in ancient buildi...

Page 9: ...oat of paint within three months of purchase and one month if basecoat stained If primed and in particular basecoat stain finishes have deteriorated because of prolonged exposure the surface must be properly prepared and re primed before finishing and a knotting solution should be applied over any visible knots Take care not to paint over any form of weatherstrip as this will adversely affect the ...

Page 10: ...o repairs or alterations to the surrounding buildings have occurred which are detrimental to the joinery performance No failure of the coating has occurred caused by failure of ancillary products or glazing No damage to the coatings has occurred prior to or during installation No damage to the coating has occurred caused by bad maintenance of the building or poor design of the building JWW3203_187...

Page 11: ...b and level Have you fitted the window in too small an opening pinching the frame Has the handle been properly engaged Are you using the correct key How do I adjust the window height width If you have ordered the window too large for the opening a new window should be ordered Taking care to ensure correct dimensions guidance is given within the JELD WEN catalogue Any alteration to the product size...

Page 12: ...Bar Oak Casement SS MF JWW 3203 NOV20 18708 www jeld wen co uk STORMSURE STORMSURE ENERGY REGENCY FITTING FIXING GUIDELINES 04 NOV20 JWW3203_18708_Stormsure Energy _Fit_instruct_A5 indd 12 JWW3203_18708_Stormsure Energy _Fit_instruct_A5 indd 12 09 02 2021 11 52 09 02 2021 11 52 ...

Reviews: