BIAS Function

This function is for revising the temp diffrence caused by
the temp sensor or other sources.
Press Temp button for six times to move the bias function.

Displayed the revised value on

the PV display and Bias on the SV

display.

① Use UP button and Down button

to move the BIAS value display.

Displayed the PV on the SV

display. Set the temp measured

by the thermometer.

② Press Enter button to complete

the BIAS function. The value

can

be

checked

on

the

BIAS

display.

③ Press Enter button once, the

unit

starts

controlling

the

temp by set value.

Use the thermometer

approved. When the

temp revision is not

done,

Contact

the

service department.

Summary of Contents for Lab companion SI-300

Page 1: ...underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos I...

Page 2: ...jects to maintain the product s functions and to use it safely Especially be sure to read Safety Precaution carefully before you use this equipment Please keep this instruction close to the equipment...

Page 3: ...sufficient points error and omission on the operating instruction Warning mark of the product 1 This operating instruction uses the warning Signal Word for safe operation to prevent the users from acc...

Page 4: ...t becomes the cause of electric shocks fires and improper operations 5 Please contact the agent or us in case of the component and the consumable parts of the product will be replaced 6 Do not give a...

Page 5: ...maged contact the delivery service company immediately 2 Keep the condition as it delivered and wait for the confirmation by the carrier 3 Within 15 days submit an application be made in writing to th...

Page 6: ...npacking the unit check the following components In addition check the features and electric condition Components EA Components EA unit 1 Power Cord 1 Operating instruction 1 Fuse 2 Software CD for co...

Page 7: ...ition of SI 300R 600R 11 5 Introduction 13 6 Controller instruction 16 7 How to change the orbital motion and reciprocation motion 38 8 Accessories 39 9 Cause of malfunction and its repairs 46 10 Insp...

Page 8: ...dent line 100V 120V 230V single phase a grounded and polarized 100V 120V 16AWG 12A 1 25SQ 230V 18AWG 10A 0 75SQ 5 Do not install the product in the place that the gas could leak out 6 Do not use in th...

Page 9: ...he product in a dangerous article area 12 Never put inflammables and explosives in the product A sample may explode in the chamber at a high temperature The explosives are acetic acid ester nitro comp...

Page 10: ...c shock or fire 6 Do not clean it with a strong cleanser like solvent type and use a soft cloth It may cause fire or modification of the product Clean it with a soft cloth dipping in neutral detergent...

Page 11: ...ed in the same place below until disusing the product If the safety alerts are damaged please request new labels to an agent or us Caution It shows the caution when opening and shutting the inner clas...

Page 12: ...mponents is isolated by a magnetic switch leaving only the earth in circuit Details of the fault are displayed indicator codes Audio and visual alarms are set off to alert the user and remain on until...

Page 13: ...he open cover we are using a translucent acrylic cover and setting a lamp up Programmed auto run function Our integrated controller allows controlling the inner circulating fan speed on three steps Th...

Page 14: ...r temp LED illuminates with audible Beep sound When the power is shut down Please set the Knob over 15 than the setting value Press the Start Stop switch and then Check the Temp LED illumination 3 Com...

Page 15: ...s the Microprocessor CPU can be performed Digital PID Auto tuning 12 Chamber Air Out Inner air is out to go through the heater or Evaporator 13 Temperature Sensor With Thin Film PT 100 14 Blower Inner...

Page 16: ...is for protecting the unit from the momentary overpower When exchanging the Fuse check the main power Model Electric requirements Fuse Quantity Remarks 100V 50 60Hz 2 EA 120V 60Hz AC 250V 10A Slow blo...

Page 17: ...e operator can use the Temp shaking function simultaneously Know well the operator to perform functions like temp shaking programmed all on the controller in right process 1 PV Display Indicates the p...

Page 18: ...es when pressing the START STOP Button Heater LED Indicates the heater output Auto tune LED Flahses during Auto tune function Wait on timer LED After setting time indicates starting point of the unit...

Page 19: ...utton Auto tune Function operates while pressing the button for a second SHAKE SET Button For Checkng the setting and present rpm and entering the new rpm value START STOP Button Starts and Stops the...

Page 20: ...lue Starts the operation Control of the Temperature This control is for the chamber of the inner temp Controlling the temp other function and programming temp using of the Temp button Method of the se...

Page 21: ...er button to finish setting Select the temp can be restored in CPU The PV temp will be changed Press Temp button once SV2 is displayed on the PV display Set the desired temp same as No 1 Press Temp bu...

Page 22: ...n case of the main screen Press the TEMP button twice Press Enter button once to display SV3 On the PV display After checking the SV 2 temp Press Enter button Press START STOP button to reoperate the...

Page 23: ...Bias on the SV display Use UP button and Down button to move the BIAS value display Displayed the PV on the SV display Set the temp measured by the thermometer Press Enter button to complete the BIAS...

Page 24: ...n screen Press Timer button twice Off Timer can be set Press Up button and Down button to set the desired time Press button to finish Illuminates W ON LED with Beep sound after setting Cancellation of...

Page 25: ...rts operation automatically after power is on Use Up button Dwon button Select YES or NO When setting YES the unit starts operation after power is on Fan speed controller function Press TIMER Button f...

Page 26: ...rating the program Input No 0 Press Up button and Down button to select the desired value Press Enter button to finish the menu SEg L is for deviding the segment If input 3 NO 3 Prgram will repeate fr...

Page 27: ...nd Temp 3 be set This program function can be set till Prg 9 If input the time 00 00 in Prg3 the program is finished The program will be operated until Prg2 and step 2 Example of Prgrammed Control Inp...

Page 28: ...minating A T LED Press START STOP butoon illuminating Run LED Auto Tunie will operate with flashing A T LED Auto tune time will be different depends on the circumtance After finishing the Auto tune Th...

Page 29: ...or rotate without the timer mode Press SHAKE SET button RPM displayed on the PV the previous rpm value displayed on the SV Use Up button and Down button to select the desired rpm Press Enter button to...

Page 30: ...d Down button Press Enter button to finish the mode Maximum Input time 1 999 hours Whole time MM SS set Set the minute and seconds Press SHAKE SET button three times run S will be appeared on PV displ...

Page 31: ...E SET button five times bAc S will be appeared on PV display The previous time will be displayed on the SV Use Up button and Dwon button To set the time then Press Button TheB WARD LED illuminates Max...

Page 32: ...press the START STOP button or The Shaker I O button The whole time set Forward or Backward Action SHAKE LED illumination Forward LED or Backward LED illumination Select the hour or minutes in the who...

Page 33: ...WARD LED 3 After setting the backward time Press Enter button to iluuminate F WARD LED or B WARD LED 4 Press the START STOP button the shkae operates the forward direction When the speed is a little s...

Page 34: ...ward time orB WARD Press Enter button to iluuminate F WARD LED or B WARD LED 3 After setting the pause time Press Enter button to iluuminate PAUSE LED 4 Press the START STOP button the shaker operates...

Page 35: ...until the set time The caution of the Timer Function When using the Timer fuction set each set value then must press Enter button to illuminate Display LED Even if illuminate SHAKE LED the shaker does...

Page 36: ...ment display Function This Function is for displaying the presnt shaking table When maintaing rpm the display starts a circular movement Forward accelation Forward deceleration Backward accelation Bac...

Page 37: ...tton with YES on the SV display the Shaker Incubator operates at the same time Set No on the SV display The shaker doesn t operate Even if setting YES on the SV display the Shaker function can be On O...

Page 38: ...with Shake Set button Reference Page 22 Press SHAKE SET button the shaking table and incubator operates together Temp Controller Incubator only Select No on SV display Press Temp button to set the de...

Page 39: ...ed on the Vibration Frame Connect the Spacer referred Page 6 to the Vibrating Frame for linear motion Position the Shaking Table on the Spacer tight 4 pieces of 5mm Wrench Bolt The basic usage is the...

Page 40: ...ries 1 Flask Clamp installed Capacities and Drawings Model SI 300 300R 50 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 28 EA 100 Flask Flask Clamp Location of fixed holes Maximum fi...

Page 41: ...Page 40 Model SI 300 300R 250 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 13 EA 500 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 9 EA...

Page 42: ...Page 41 Model SI 300 300R 1 000 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 4 EA 2 000 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 2 EA...

Page 43: ...Page 42 Model SI 600 600R 50 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 45 EA 100 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 36 EA...

Page 44: ...Page 43 Model SI 600 600R 250 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 18 EA 500 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 13 EA...

Page 45: ...Page 44 Model SI 600 600R 1 000 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 7 EA 2 000 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 5 EA...

Page 46: ...4 EA 2000 1 EA SI 600 600R Flask Max Capacities EA Flask Max Capacities EA 50 25 EA 500 5 EA 100 16 EA 1000 4 EA 250 9 EA 2000 2 EA 3 Test tube rack Setting angle Model 0 60 Platform size SI 300R 2 E...

Page 47: ...Check the W ON LED is illuminated Release the Timer mode Check the dust on the Condenser Clean the filter opened the Condenser cover The temperature doesn t decrease Check the inner circulation fan sp...

Page 48: ...op button after currently adjusting than temperature PV higher than 15 red of O T Led disappears and a Beep sound disappears 2 While Run LED and Heater LED are on if they press one time of Start Stop...

Page 49: ...stops operation by START STOP Check Sync Parameter is no Reference Page 36 37 Select Sync Parameter is yes or Press Shaker I O Switch to operate When the shaker speed is up or down the display has any...

Page 50: ...Condition Shaker Noise Air Filter Cleaning Vibration Be sure to maintain the unit frequently by a person authorized Make no attempt to service or repair the unit when the power is on Be danger of Do n...

Page 51: ...1 Wipe the exterior surface with a clean sponge or a soft fabric using a detergent 2 Rinse off with a dry fabric using a tepid water 3 Clean the controller Panel with a dry fabric Do not use sulfuric...

Page 52: ...Pause Forward Backward Max 59min 59sec Min 10sec Shaking Driving System Brushless DC motor with feedback control Internal Stainless Steel 1 0t External Steel 3 2t 2 0t powder coating Platform Anodize...

Page 53: ...y warranty in case of as below If the machine is broken due to the Act s of God If the machine is broken due to overuse of voltage If there is some shock to the machine If the outer part is damaged by...

Page 54: ...rts Model Gross Weight kg External dimension mm W D H How to waste Main body SI 300 74kg 420 740 622 Main body SI 300R 85kg 420 740 622 Main body SI 600 91kg 540 842 622 Main body SI 600R 102kg 540 84...

Page 55: ...e term of guarantee if as follows Purchase date Serial number A trouble part and trouble state Equipments use environment A use mistake of a user A mistake of treatment of a user and custody Unfair ch...

Page 56: ...tion Default folder recommended 3 Click Install to start installation 4 Lab Tracer icon will be created on the desktop after successful installation 5 To start Lab Tracer double click the icon Standar...

Page 57: ...consists of 2 separate windows Window on the top displays set temperatures and actual temperatures and window on the bottom displays output value of heating in a graph mode 2 View menu 2 1 If you cli...

Page 58: ...ing Status and Parameter in View menu User can monitor operating process through three divided windows Graph Parameter Status 2 2 1 Graph displays Actual temperatures Red line and set temperatures Blu...

Page 59: ...or not 2 2 3 Parameter displays 1 PV is an actual present temperature 2 SV is a set temperature 3 Heat is an output value of heating element 4 Run Time indicates operating time after you press button...

Page 60: ...pearance of displayed panel of unit pops up and you can control the unit by the pop up window 17 Set Pattern of Program Run Set Pattern of Program Run and makes unit in a programmable operation Maximu...

Page 61: ...f not they will not be printed Current page Print a page on the current main screen Selected pages Print selected page s Number of copies Maximum number of copies is 100 by pressing up and down button...

Page 62: ...regular interval like the preview above If user wants to check a certain point move curser to the point and click Green line with PV and SV will be printed on the copies see above Last Point Delete De...

Page 63: ...on the left side of window Display All the functions of display window are same as those of main display panel If communication via RS 232 between PC and main body is connected user can control main b...

Page 64: ...egree and time can be adjusted by one minute Short key Increase temperature by 1 degree Decrease temperature by 1 degree Decrease time by 1 minute Increase time by 1 minute Alt Move an edited point to...

Page 65: ...ate ii The main body must be set as a Con P mode To convert to Con P mode press and hold the lock button for more than 1 second If you want to operate the unit in Con L mode Local mode press and hold...

Page 66: ...over 99 hours the unit does not operate in a Program Mode Especially be cautious when you program a pattern repetition Please be aware of specification about program time and temperature If you progra...

Page 67: ...Page 66...

Page 68: ...Page 67...

Page 69: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: