BM-12 Bevelling Machine
- 11 -
THE CARBON BRUSHES
The carbon brushes are a normal wearing part and must be replaced when they
reach their wear limit.
Caution: Always replace the brushes as a pair
To Replace:
First unplug the machine. Carefully remove the 4 screws to separate the rear
handle halves and then remove the 4 screws which connect the handle to the
motor housing. Lift away the left-hand handle half first. There will still be wired
connected to the rear handle, so take care that these are not stressed. Simply
hold the rear handle off to one side.
Using pilers, rotate the brush spring out of the way and slide old carbon brushes
out of the brush holder. Unplug the spade connector to remove the brush lead.
The old carbon brush may now be lifted away. Replacing is the opposite of
removal. When replacing the rear handle to the motor housing, take great care
that all wires are in place and not in a position to be pinched when it is
retightened.
If the replacement of the power supply cord is necessary, this has to be done by
the manufacturer or their agent in order to avoid a safety hazard.