8
USER MANUAL
v1.1
JEFARIVT02H
AIR-HYDRAULIC BLIND RIVETER
www.jeffersontools.com
TROUBLESHOOTING
Factors That May Inhibit Performance:
•
Loss of power or erratic action may be caused by reduced compressor output, an excessive drain on the air line,
moisture or restrictions in air pipes or the use of hose connections of improper size.
•
Grit or gum deposits in the tool may cut power and can be corrected by cleaning the air strainer and flushing out
the tool with gum solvent oil or an equivalent de-greaser.
•
If all outside conditions are in order, disconnect the tool from the air supply, disassemble and replace any worn or
damaged parts with Jefferson approved parts.
•
Clean all parts, reassemble the tool and lubricate.
•
Store the tool in a safe, dry, secure environment.
Symptom
Possible Causes
Solution
Rivet jammed.
1. Wrong size for rivet/nozzle.
2. Filings jammed in jaw housing.
3. Filings jammed in nozzle.
1. Use correct size nozzle for the rivet.
2. Snap off rivet head, dismantle jaw housing
and pull out the rivet mandrel. Use an
airline to blow out the filings, oil and
reassemble the jaw housing.
3. Clean out the nozzle.
No suction.
1. The shut-off valve has not been
opened.
1. Open shut-off valve.
Air leaking.
1. Loose screws.
2. Damaged O-rings.
1. Tighten screws.
2. O-rings must be replaced.
Tool runs slow or suffers a
loss of power.
1. Air line is loose.
2. Exhaust port is blocked.
3. Operating pressure is too low.
1. Re-install and tighten air line.
2. Clean out exhaust port.
3. Increase the operating pressure to 85-
95psi. If the pressure exceeds 105-110psi,
the safety valve will be activated.
Summary of Contents for JEFARIVT02H