background image

7

USER MANUAL

 v1.1 

JEFARIVT02H

AIR-HYDRAULIC BLIND RIVETER

www.jeffersontools.com

Fig.4

Fig.5

Fig.6

Fig.7

Fig.8

Fig.9

Operation 

Ensure the air valve is in the closed position before connecting the air 
supply: 

 Open the shut-off valve by sliding the knurled ring upwards as shown 

in the diagram to the right.

 Insert the desired size rivet into the nozzle, ensuring the appropriate 

nozzle is fitted first.  

 Insert the rivet into the workpiece as far as it will go and squeeze the 

trigger. 

 The rivet will be compressed and the spent mandrel will be sucked into 

the spent mandrel bottle. 

 When the spent mandrel bottle is full, close the shut-off

valve, unscrew, empty and replace as shown in 

Fig.4

.

  MAINTENANCE

IMPORTANT: 

 Ensure you disconnect the tool from the air supply system before attempting any maintenance.

General Maintenance

 Ensure that the riveter is kept in good clean condition. Check condition prior to use. Do not use the equipment if 

damage is detected. Contact Jefferson tools for advice on repair and replacement parts. 

 Maintain the tool with care. 

 Keep the equipment well oiled for optimum performance.

Lubrication

• Lubricate the air tool daily with a suitable high quality air tool oil 
(for example SAE 10). Please refer to the parts diagram shown on 
pg.10 for reference. 
• Unscrew and remove the frame head (Part #38) and cylinder cap 
(Part #1A) using 2x Ø5.1mm rods as shown in 

Fig.5. 

Remove the 

air piston (Part #7A). Using the oil can supplied, fill the reservoir 
with oil until the oil level reaches the o-ring (Part #18). Inspect, 
clean or replace the oil seal as required during this procedure. 
• Re-fit the cylinder cap and reassemble the jaw housing and 
adjust the length to match the spanner gauge (Part #63) and fix 
the frame head as shown in 

Fig.9

.

Jaw Replacement

  After a period of use the jaws on the riveter will wear and 

require replacement.

 To replace, first remove the nozzle and frame head using 

the spanners supplied as shown in 

Fig.6.

 Undo and remove the jaw housing from the jaw housing (

Fig.7 - Fig.8)

 Remove the worn jaws and replace with a new set. If the 

jaw pusher and spring fall out, put the spring back first and 
then the jaw pusher followed by the jaws. 

 Fit the frame head and tighten.

 When the jaws are replaced check that the jaw distance 

from the main body is 84mm using the guide on the 
spanner as shown in 

Fig.9

.

Oil Level 

Summary of Contents for JEFARIVT02H

Page 1: ...OLYMPUS User Manual v 1 1 JEFARIVT02H AIR HYDRAULIC BLIND RIVETER...

Page 2: ......

Page 3: ...e We recommend that you read the information supplied before carrying out any maintenance or repair By following all the general safety instructions contained in this manual you will help to ensure op...

Page 4: ...les 4 8mm 3 16 5 6mm 7 32 6 4mm 1 4 Weight 1 9kg Sound Power Level The figures quoted in this table are emission sound power levels and are not necessarily safe working levels Whilst there is a correl...

Page 5: ...s Keep the air hose away from heat oil and sharp edges Check air hose for wear before each use and ensure that all connections are secure before use Remove ill fitting clothing ties watches rings loos...

Page 6: ...Line pressure should be increased to compensate for unusually long air hoses over 8 metres The minimum hose diameter should be 1 4 I D and fittings must have the same inside dimensions Ensure that th...

Page 7: ...uipment well oiled for optimum performance Lubrication Lubricate the air tool daily with a suitable high quality air tool oil for example SAE 10 Please refer to the parts diagram shown on pg 10 for re...

Page 8: ...semble the tool and lubricate Store the tool in a safe dry secure environment Symptom Possible Causes Solution Rivet jammed 1 Wrong size for rivet nozzle 2 Filings jammed in jaw housing 3 Filings jamm...

Page 9: ...ance of the tool itself is also an important factor a poorly maintained tool will also increase the risk of Hand Arm Vibration Syndrome Health surveillance We recommend a programme of health surveilla...

Page 10: ...10 USER MANUAL v1 1 JEFARIVT02H AIR HYDRAULIC BLIND RIVETER www jeffersontools com PARTS DIAGRAM...

Page 11: ...1 O RING 9 8 13 6 1 9 42 JAW HOUSING COUPLER 11A O RING 43 SPRING 13 TUBE 44 PISTON SHAFT 14 ROD 45 INT TOOTH WASHER 15A STEM NUT 46 CASE LOCK NUT M10 17 BACK UP RING 49 OIL SEAL WASHER 18 O RING 11 8...

Page 12: ...d as it eliminates the need to provide proof of purchase should a warranty claim be necessary Warranty Repair Should Jefferson confirm the existence of any defect covered by this warranty the defect w...

Page 13: ...d of repair and any repairs needed are covered by the warranty policy In order to qualify for warranty cover all equipment presented must have been used serviced and maintained as instructed in the us...

Page 14: ...11178 1 2011 EN ISO 20643 2008 A1 2012 Principles for evaluation of vibration emission EN ISO 15744 2008 Hand held non electric power tools Noise measurement code Engineering method grade 2 Equipment...

Page 15: ......

Page 16: ...44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating instructions outlined in this manual...

Reviews: