background image

 

 

Tap right to select the 

RFC 2544 Settings

. Make 

sure that   

   

 

Load Format -> Bit Rate 

 

Auto Save Report -> Enable 

 

Auto Restore Cfg* -> Disable 

You can also enter the customer, location, 

technician and any comments you have that you 
wish to be stored on the final report.

 

 

 

 

Tap right to select the 

Test Selections

. Make sure 

that   

   

 

Throughput -> Enable 

 

Latency (RTD)* -> Enable 

 

Packet Jitter * -> Enable 

 

Frame Loss -> Enable 

 

Back to Back -> Disable 

 

Max Bandwidth -> this will change at each 
location but should be the CIR for the circuit. 

 

 

Tap right to select the 

Frame Length Tab

. Make 

sure that   

   

 

The smallest possible Frame Length is selected 
(this will be either 64, 68, 70, or 72 depending 
on the settings).  To do this go to Frame Length 
1 and select the value. 

 

Select 512 entry 4. 

 

Select 1518 or 1522 (whichever one you are 
allowed to select) in entry 7. 

 

Make all the rest of the entries disabled 

 

Please see picture for a correct sample setup.   

 

Tap right to select the 

Throughput

. Make sure 

that   

   

 

Accuracy -> To within 0.1 (Mbps) 

 

Test Dur. -> 120 sec 

 

Frame Loss Tol -> 0Mbps 

 

Show Pass/Fail -> No 

 

Zero in Method -> JDSU Enhanced 

 

 

Summary of Contents for IP Video Test Option HST-3000

Page 1: ...lts key to display the results of the scope image 4 Turn the focus control on the probe to focus the image on the display 5 There should not be any dirt on the image If there is dirt clean the fiber a...

Page 2: ...erminate 2 The unit will now boot up Make sure to insert the proper SFP into the R T 1 slot top left of the unit The proper SFP will be either a 1310nm or 850nm optical SFP depending on the handoff 3...

Page 3: ...se do so at this time 2 Press the configure button Tap the left and right arrows until you get to the Summary Settings Screen Then Select Loop Type Broadcast Tx Payload Acterna Frame Length Random Enc...

Page 4: ...ct 2 Loop and then Select 1 Loop Up 8 You should see a message at the top stating Remote Loop Up Successful If you do not see this message please double check your settings If the message still does n...

Page 5: ...describes how to validate the link between two locations The output of this test is a go or no go on the quality of the link and the results can be saved for further analysis This section is expected...

Page 6: ...will change at each location but should be the CIR for the circuit 5 Tap right to select the Frame Length Tab Make sure that The smallest possible Frame Length is selected this will be either 64 68 70...

Page 7: ...9 Tap right to select the Frame Loss Make sure that Test Procedure RFC 2544 Trial Dur 60 sec Test Granularity 10 Mbps 10 Next press the home key Then select Restart 11 Now select the Action key and t...

Page 8: ...rn on the HST 3000 3 Press the System Navigation key and press the TOOLS soft key Press the Up Arrow or Down Arrow key to select File Manager then press the OK key to manage user files in the file sys...