background image

 

 

The tester is now ready to receive loop commands or proceed to Quick Testing using 

the HST-3000 (Section 3)

 

 

3  Quick Testing Using the HST-3000 

This section describes how to quickly check an active link exists between two test sets.  This test 
proves that the link exists and will detect if errors occur.  After this section is complete one can 
safely run the RFC 2544 test to validate the pipe.   

 

Step 

Directions 

 

This section continues from section 2 and having setup both ends of the link.  If you 

have not completed the appropriate section, please do so at this time.   

 

 

 

Press the 

configure 

button.  Tap the left and 

right arrows until you get to the 

Summary 

Settings

 Screen.   

 
Then Select: 

 

Loop Type -> Broadcast 

 

Tx Payload -> Acterna 

 

Frame Length -> Random 

 

Encapsulation -> Most Likely this will 

be VLAN tagged though it depends on the 
location and network 

 

VLAN ID and Priority -> Depends on 

Network, see work order 

 

Traffic Load -> again depends on 

network, see work order.  If unknown enter 1%. 

 

Tap the Right arrow until you get the Ethernet Tab.  

Select Frame Type -> DIX.  

 

 

Please note that if you are running across a switched service you have to set the 

Destination MAC equal to the far end’s Source MAC address on both testsets. 

 

Tab right to select the Error Page. 
Make sure that 

 

Error Type -> FCS 

 

Insertion Type -> Single 

 

 

Summary of Contents for IP Video Test Option HST-3000

Page 1: ...lts key to display the results of the scope image 4 Turn the focus control on the probe to focus the image on the display 5 There should not be any dirt on the image If there is dirt clean the fiber a...

Page 2: ...erminate 2 The unit will now boot up Make sure to insert the proper SFP into the R T 1 slot top left of the unit The proper SFP will be either a 1310nm or 850nm optical SFP depending on the handoff 3...

Page 3: ...se do so at this time 2 Press the configure button Tap the left and right arrows until you get to the Summary Settings Screen Then Select Loop Type Broadcast Tx Payload Acterna Frame Length Random Enc...

Page 4: ...ct 2 Loop and then Select 1 Loop Up 8 You should see a message at the top stating Remote Loop Up Successful If you do not see this message please double check your settings If the message still does n...

Page 5: ...describes how to validate the link between two locations The output of this test is a go or no go on the quality of the link and the results can be saved for further analysis This section is expected...

Page 6: ...will change at each location but should be the CIR for the circuit 5 Tap right to select the Frame Length Tab Make sure that The smallest possible Frame Length is selected this will be either 64 68 70...

Page 7: ...9 Tap right to select the Frame Loss Make sure that Test Procedure RFC 2544 Trial Dur 60 sec Test Granularity 10 Mbps 10 Next press the home key Then select Restart 11 Now select the Action key and t...

Page 8: ...rn on the HST 3000 3 Press the System Navigation key and press the TOOLS soft key Press the Up Arrow or Down Arrow key to select File Manager then press the OK key to manage user files in the file sys...

Reviews: