Display.messages
Cause
Action
Err.19
Error water system:
Check the water supply line to the dispenser is blocked,
open the water tap completely.
Press the LOCK/Clear-Error switch.
Contact service, if the error remains.
Err.30
Errors cooling:
Check the ventilation and the ambient temperature
of the dispenser, and clean the ventilation grid, if
necessary.
Press the LOCK/Clear-Error switch.
Contact service, if the error remains.
Err.60
Error mixing console:
Check the position of the mixing console and correct it
(release and close), if necessary
Err.61
Error mixing bowl:
Check the position of the mixing bowl and correct it, if
necessary
Contact service, if the error remains.
Water leaks from the hot
water outlet or a product
outlet.
Scale particles block the respective
outlet valve, it cannot close
completely.
Perform the program ‚Flushing‘.
Contact service if the problem persists.
The dispenser does not
respond to pressing a
button or touch screen
input.
A software jam has occured.
Reset the dispenser:
Disconnect the power supply and connect again after 5
seconds.
Contact service if the problem persists.
2014 - 03
49
7 DISPLAY MESSAGES AND TROUBLE SHOOTING