TAIKO Service Manual
4-8
CHAPTER
4
© 2006 Japan Cash Machine Co.Ltd. All rights reserved.
4-3. Adjustment
You learn how to adjust TAIKO Unit in this section. After Software Program is down-
loaded or CPU/Sensor/Interrapt Board is replaced, the TAIKO Unit needs to be adjusted.
4-3-1. Requirements
When adjusting, the following items are required.
- TAIKO Unit
- Reference Paper(Part#: KS-070, EDP#: 119581)
- JCM Power Supply Unit *1
- TAIKO Harness A *2
- VM-450 Connection Harness *2
*1,2 Use a test bench and a harness instead of the power supply. A test bench and a harness
to be decided by each specification. To identify each specification, refer to following
table.
A.ID-003/MDB/Pulse/ccTalk
A1:JCM Power Supply Unit(Part#: VM-30, EDP#: 116125) or equivalent
A2:TAIKO Harness A(Part#: 3280-05-54, EDP#: 127527)
B.ID-001
B1:JCM Power Supply Unit(Part#: VM-450, EDP#: 059307) or equivalent
B2:VM-450 Connection Harness(Part#: 3280-05-102, EDP#: N/A)
- When the TAIKO Unit is installed to the Host Machine, the Power
Supply Unit (A1 , B1), the TAIKO Harness A ( A2) and the VM-450
Connection Harness( B2) are not required.
Interface
Operation Label
(Interface)
Interface
Connector
Option
Connector
ID‑001
01
White
No
X4
Black
Yes
ID‑003
MDB
Pulse
ccTalk