Lecture Notes
A
GING
T
EST
Perform the following steps to repeatedly test the VEGA's basic feeding, trans-
porting, and stacking functions:
1. Ensure the VEGA's power is
OFF
.
2. Set DS1, Switches #1, #2 & #4
ON
.
3. Apply power to the VEGA.
4. Set DS1, Switch #1
OFF
. This begins the Aging Test.
5. If operation is normal, the Unit will perform the following five functions repeti-
tively:
a. Feed Motor Reverse Rotation
b. Interval Test (20 sec. LED Lights White)
c. Feed Motor Forward Rotation
d. Stacking Test
e. Interval Test (20 sec. LED Lights White).
6. To end the test, set DS1, Switch #1
ON
.
S
ENSOR
T
EST
Perform the following steps to verify if the eight (8) Sensors within the VEGA
are functional:
1. Ensure the VEGA's power is
OFF
.
2. Set DS1, Switches #1, #2, #3, #4 & #5
ON
.
3. Apply power to the VEGA.
4. Set DS1, Switch #1
OFF
. This begins the Sensor Test.
Table 7
Stacker Motor Error Codes
LED Color Blink Sequence
Error Indication
WHITE
3
Feed Motor Low Speed Problem
5
Feed Motor High Speed Problem
7
Feed Motor Lock-Up
RED
5
Cash Box Seating Problem
PURPLE
5
Stacker Motor Lock-up
7
Stacker Motor Gear Problem
ORANGE
3
Stacker Full
NOTE: If the Front Panel LED blinks any error sequence listed in Table 7, the
Stacker Motor's Rotation is abnormal.